Industrial Power Supplies TSP-WR Series, 180 600 Watt CB Scheme For global use with single- and two phase EMC IEC 60950-1 UL 60950-1 LVD UL 508 wide-range input 100/230500 VAC Rugged metal case for harsh industrial environments Industrial operating temperature range: 25C to +70C Power OK signal Remote On/Off Shock and vibration-proof Indenfi ite short circuit, overvoltage and overtemperature protection Redundancy module Buffer module for power backup Battery controller module 3-year product warranty The successful TSP series of high performance DIN-rail mount power sup- plies has been expanded with models featuring wide input ranges of 85-132 / 187-264 / 323-550 VAC. With these input ranges the power supplies can be used in almost all single- and multi phase power networks worldwide. A high, continuously available power reserve guarantees reliable start-up of loa- ds with high inrush currents. Excellent electrical specicfi ations and high immunity against electrical disturbances make these compact power supplies the best choice to power sensitive loads in industrial process control systems, machine tools or any other demanding industrial application. The power supplies comply also with IEC/EN 61204-3, the EMC standard for Industrial environment. 3 add-on modules for extra functions offer a great flexibility in system applications. A module for redundant operation with true power sharing is available. With the battery controller module the power supplies can be extended to a perfect DC-UPS system. The buffer module provides power back-up for up to 4 seconds without the need of any batteries. Easy and vibration proof installation with pluggable screw terminal block and snap-on mounting on DIN-rails. Models Order Code Output Voltage *Output Current Output Power (Vnom) (Imax) (Pmax) TSP 180124WR 7.5 A 180 W 24 VDC TSP 360124WR 15.0 A 360 W (adjustable 24 - 28 VDC) TSP 600124WR 25.0 A 600 W * Max. current at nominal output voltage and operating temperature up to 40C max. TSP-WR Series, 180600 Watt Input Specifications Applicable 3-phase networks TN, TT Systems: 500 VAC Star configuration (EN60950, UL508) 500 VAC Delta (UL508 only) IT Systems: 400 VAC Delta (IEC-62103) 230 VAC Delta (IEC-60950) 500 VAC (UL508) Input ranges select (low/high) by manual switch: 85132 VAC / 187...550 VAC auto range selection in high ranges: 187264 VAC / 323550 VAC input frequency: 4763 Hz Harmonic limits EN 61000-3-2, Class A (for limited output power) Holdup time 20 ms min. (full load 230 500 VAC) Inrush current TSP 180-124WR < 23 A TSP 360-124WR < 46 A TSP 600-124WR < 50 A Efficiency 88 % typ. Output Specifications Output voltage adjustable range 2428 VDC Regulation Input variation 0.5 % max. Load variation (10100 %) 0.5 % max. Load variation (10100 %) parallel mode 2.0% Ripple and noise (20MHz bandwidth) 100 mV pk-pk typ. (150 mV pk-pk max. at Imax) Electronic short circuit protection current limitation at 125 % of Imax. constant current, automatic recovery Output overvoltage protection 34 V Overload protection electronic overload protection Overtemperature protection switch off at overtemperature, automatic restart Status indicator dual colour LED (green: DC OK, red: DC off) Power OK signal trigger threshold 18 22 V relay output DC OK = contact closed (rated: 30 VDC/1.0 A) Max. capacitive load unlimited General Specifications Operating temperature range 25C to +70C max. (for derating see graph A on page 3) Cooling convection cooling, no internal fan Storage temperature 25C to +85C Humidity (non condensing) 95 % rel. H max. Pollution degree 2 Temperature coefficient 0.02 %/K Reliability, calculated MTBF at +25C acc. to IEC 61709 >350000 houres in accordance to IEC 61709 Remote On/Off by ext. contact. DC on: -S contact open DC off: -S connected via 1 Kohm to -Vout Safety standards Information technology equipment IEC/EN 60950-1, UL 60950-1, CSA-C22.2 No. 60950-1-03, CSA-C22.2 No. 107.1-01 Industrial control equipment UL 508 Electrical equipment of machines EN 60204 Electronic equipment for power installation EN 50178 Safety transformers for SMPS EN 61558-2-16