AC/DC Enclosed Power Supply TXL 060/070 Series, 50-70 Watt Compact metal case with screw terminal block Multiple output models with isolated outputs Universal input 85 264 Vac EMI/EMC compliance with EN 61000-6-3 and EN 61000-6-1 Compliance to EN 61000-3-2 Short circuit and overvoltage protection International safety approvals CB 3 year product warranty Scheme UL 60950-1 The TRACO POWER TXL series is a family of encased power supplies designed for a wide range of cost critical applications. With a low profile metal case and screw terminal block connection, they are easy to install in any equipment. These power supplies have universal input and comply with European EMC stan- dards and the Low Voltage Directive (LVD). Models Order Code Power Output voltage Output current max. Efciencfi y max. Vout 1 Vout 2 Vout 3 Vout 1 Vout 2 Vout 3 typ. Models TXL 060-3.3S 50 W 3.3 VDC 15.0 A 74 % TXL 060-05S 60 W 5 VDC 12.0 A 77 % TXL 070-12S 72 W 12 VDC 6.0 A 83 % TXL 070-15S 72 W 15 VDC 4.8 A 84 % TXL 070-24S 72 W 24 VDC 3.0 A 85 % TXL 070-48S 72 W 48 VDC 1.5 A 87 % 1) TXL 060-0512DI 60 W +5 VDC +12 VDC 8.0 A 4.0 A 78 % 1) TXL 060-0524DI 60 W +5 VDC +24 VDC 6.0 A 2.2 A 79 % 1) TXL 060-0521TI 60 W +5 VDC +12 VDC 5 VDC 8.0 A 3.5 A 1.0 A 77 % 1) TXL 060-0522TI 60 W +5 VDC +12 VDC 12 VDC 7.0 A 3.5 A 1.0 A 78 % 1) TXL 060-0533TI 60 W +5 VDC +15 VDC 15 VDC 7.0 A 3.0 A 1.0 A 79 % 1) TXL 060-0534TI 60 W +5 VDC +12 VDC +24 VDC 6.0 A 1.5 A 1.2 A 80 % 1) Total power should not exceed max. output power www.tracopower.com Page 1 of 4 TXL 060/070 Series, 50-70 Watt Input Specifications Input voltage range nominal 100 240 VAC AC range (universal input) 85 264 VAC DC range 120 375 VDC Input frequency 47 63 Hz Input current at full load at 100 VAC 1.8 A max. Input inrush current at 115 VAC / 230 VAC 30 A max. / 60 A max. Zero load power consumption only single output models: 0.75 W max. (green mode design) Recommended circuit breaker (characteristic C or slow bow fuse) 5 A Output Specifications Output voltage adjustment range 10 % (only Vout 1) Regulation Input variation 1.0 % max. Load variation (20 - 100%) main output: 2.0 % max. Vout 2, Vout 3: 5.0 % max. Minimum load single output models: not required dual output models: Vout 1 requires 1.0 A triple output models: Vout 1 requires 0.5 A Temperature coefficient 0.02 %/K Start-up time 1 s max. Rise time 20 ms max. Hold-up time at 230 VAC 60 ms min. Ripple and noise measured with external capacitors: 0.1 F and 47 F parallel capacitor (20Mhz Bandwidth) Vout 1, Vout 2, Vout 3: 3.3 & 5 Vout: 70 mVp-p typ. 12 Vout: 120 mVp-p typ. 15 Vout: 150 mVp-p typ. 24 Vout: 200 mVp-p typ. 48 Vout: 250 mVp-p typ. Overload protection by current limitation 105 150 % of Iout max. Short circuit protection hiccup mode (automatic recovery) Overvoltage protection (Latch off, recovery after restart) 115 140 % of nominal Vout (only Vout 1) Capacitive load www.tracopower.com/products/txl-capload.pdf General Specifications Temperature ranges Operating 20C to +70C (with derating) Storage 40C to +85C Output power derating Temperature 2.5 %/K above +45C Low input voltage 0.7 %/V below 100 VAC Cooling natural convection (20 lfm), no internal fan Humidity (non condensing) 20 90 % rel. H max. Altitude during operation 2000 m Isolation voltage (60 sec.) Input / Output 3000 VAC Input / PE 1500 VAC Output / PE 500 VAC Isolation resistance (at 500 VDC) 100 MOhm min. Leakage current (at 264 VAC/60Hz) 1 mA max. All specifications valid at nominal input voltage, full load and +25C after warm-up time unless otherwise stated. www.tracopower.com Page 2 of 4