Switch Mode Power Supplies Single Output AC/DC Power Supply AEU65-360 Description: The AEU65-360 is a single output power supply. This power supply is designed for a wide variety applications where high reliability is desired, including applications for the industrial and telecommunications markets. Excellent performance specifications are provided, together with compliance to European EMC (EN55022, Class B and EN61000-3-2), and Low Voltage directive. Specifications ( 25C) Input Characteristics: Input Voltage: 90-264VAC, 127-373VDC Input Frequency Range: 47-63Hz Input Current: 1.6A 115VAC, 0.8A 230VAC typ. Max Inrush Current: 30A 115VAC, 60A 230VAC at cold start Leakage Current: <2.4mA/240Vac Output Characteristics: Output Voltage: 36.0VDC1.5%Vdc Output Current (Convection): 0-1.81A Output Power (Convection): 65W Adjustable Output Range: 34.2 37.8V. Output voltage can be adjusted at VR51 1 Ripple & Noise : 300mVp-p Load Regulation: 0.5% Line Regulation: 0.5% Efficiency: 87.5% Start-up Time: 1000ms/230VAC, 2000ms/115VAC, full load Rise-up Time: 30ms/230VAC, 30ms/115VAC, full load Hold-up Time: 24ms/230VAC, 12ms/115VAC, full load Over Current Protection: 110 160%. Hiccup mode. Resets automatically once the fault condition is removed. Over Voltage Protection: 41.4 48.6VDC. General Specifications: Dimension (LxWxH): 99(3.9) x 75(3.0) x 35.0(1.38) mm (in) Weight: 200g Cooling: Natural Convection Isolation Resistance: I/PO/P, I/PFG, O/PFG: 500VDC/100M Ohms Dielectric Strength: I/PO/P:4.3KVDC I/PFG:1.5KVAC O/PFG:0.5KVAC Warranty: 3 years MTBF: 250K hrs. min. MIL-HDBK-217F (25C) Environmental Specifications: Operating Temperature: -20 to 50C at full load (Refer to output load derating curve) Operating Humidity: 20 to 90% RH, non-condensing Storage Temperature: -40 to 85C Storage Humidity: 10 to 95% RH, non-condensing Temperature Drift: <0.03%/C (0-50C) Vibration: 10-500Hz, 2G 10min/cycle, period of 60min, each X, Y & Z axis 2 EMC & Safety Specifications : EMI Emissions: Compliance to EN55022, CISPR22 Class B (Conducted & Radiated) Harmonic Current: Compliance to EN61000-3-2, 3 EMS Immunity: Compliance to EN61000-4-2, 3-6, 8 & 11 EN55024 heavy, light industry level, criteria A Safety Approval: UL 60950-1, (insulation class -1) 1 Ripple and noise are measured at 20MHz of bandwidth by using a 12 twisted-pair wire termination with a 0.1uF & 47uF parallel capacitors. 2 The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. Web: www.TriadMagnetics.com 460 Harley Knox Blvd. Phone 951-277-0757 Publish Date: September 20, 2021 Perris, California 92571 Fax 951-277-2757 Model L N COM +V (AC) Label Switch Mode Power Supplies Single Output AC/DC Power Supply Outline Dimensions (mm): 4xM3,L=4 P1 P2 P3 Screw Steel 6-32 P4 P5 2.5 14.5 43 30 110 9.5 87 NOTE 3xM3,L=4 1. All I/O connection shall Follow specified Model Label. 2.5 2. Temp =+50C (max) at full load. Model Label Connections: AC Input Connector DC Output Connector Assignment Assignment P1 AC/L P4 COM P2 AC/N P5 V+ P3 FG Block Diagram: Derating Curve: Output Derating VS Ambient Temperature Output Derating VS Input Voltage (HORIZONTAL MOUNTING) RoHS Compliance: As of manufacturing date February 2016, all standard products meet the requirements of 2015/863/EU, known as the RoHS 3 initiative. * Upon printing, this document is considered uncontrolled. Please contact Triad Magnetics website for the most current version. Web: www.TriadMagnetics.com 460 Harley Knox Blvd. Phone 951-277-0757 Publish Date: September 20, 2021 Perris, California 92571 Fax 951-277-2757 35 8.2 9.5 17.5 29.5 18.5 12.5 13 78