CLASS 2/3 TRANSFORMER F16-2250-C2 Description: The F16-2250-C2 is a single primary and dual secondary, split bobbin design which operates with an input of 115V. The secondaries are 8V 2.25A each. They can be used independently (up to 300V difference between them) or in series for double the voltage or in parallel for double the current. The split bobbin design eliminates the need for costly electrostatic shielding. Electrical Specifications ( 25C) 1. Maximum Power: 36.0VA 2. Primary: 115V, 50/60 Hz 3. Secondaries: 8.0V 2.25A each W 4. Voltage Regulation: 25% TYP full load to no load 5. Temperature Rise: 25C TYP 6. Hipot tested 100% at 4200 VRMS pri to sec 7. Hipot tested 100% at 2160 VRMS sec to sec 8. Recommended fuse (fuse on primary): Cooper/Bussman, Type MDL, rated 500mA, 250V Construction: Three flange bobbin construction with primaries and secondaries wound side by E side for low capacitive coupling. UL Class F Insulation System (155C). Agency File: L UL: File E65390, UL 5085-3 (1585), Class 2 not wet / Class 3 wet Transformer cUL: File E65390, UL 5085-3 (1585) For Canadian Use (CSA 22.2, No.66.3-06) H Dimensions: Units in inches. 1 4 H W L A B C D E F 1.562 2.187 2.625 0.400 0.400 1.850 0.041 0.020 0.234 Weight: 1.10 lbs D F Schematic: 5 A A 8V 2.25A 58 1 6 115V 50/60 Hz 7 B 4 8V 2.25A 8 C RoHS Compliance: As of manufacturing date February 2005, all standard products meet the requirements of 2011/65/EU, known as the RoHS initiative. 1 4 As of April 7, 2008, UL standards 506 and 1585 will be migrated to UL 5085-2 0.06 DIAMETER and 5085-3, respectively. HOLE Board Layout * Upon printing, this document is considered uncontrolled. Please contact Triad Magnetics website for the most current version. www.TriadMagnetics.com 460 Harley Knox Blvd. Phone: (951) 277-0757 Publish Date: December 4, 2013 Perris, California 92571 Fax: (951) 277-2757