CLASS 3 TRANSFORMER
F36-1000-C2
Description:
The F36-1000-C2 is a single primary and dual secondary, split bobbin design which
operates with an input of 115V. The secondaries are 18V @ 1.0A each. They can
be used independently (up to 300V difference between them) or in series for double
the voltage or in parallel for double the current. The split bobbin design eliminates
the need for costly electrostatic shielding.
Electrical Specifications (@25C)
1. Maximum Power: 36.0VA
2. Primary: 115V
3. Secondaries: 18.0V @ 1.0A each
W
4. Voltage Regulation: 25% TYP @ full load to no load
5. Temperature Rise: 25C TYP
6. Hipot tested 100% at 4200 VRMS pri to sec
7. Hipot tested 100% at 2160 VRMS sec to sec
8. Recommended fuse (fuse on primary): Cooper/Bussman, Type MDL, rated
500mA, 250V
Construction:
Three flange bobbin construction with primaries and secondaries wound side by
side for low capacitive coupling. UL Class F Insulation System (155C).
E
Agency File:
UL: File E65390, UL 5085-1 & 3 (1585), Class 3 Transformer
L
cUL: File E65390, UL 5085-1 & 3 (1585) For Canadian Use (CSA 22.2, No.66.3-06)
H
Dimensions: Units in inches.
1 4
H W L A B C D E F
1.562 2.187 2.625 0.400 0.400 1.850 0.041 0.020 0.234
Weight: 1.10 lbs
D
F
Schematic:
5
18V @ 1.0A
A A
1
6
115V 58
50/60 Hz
7
4
18V @ 1.0A
B
8
C
RoHS Compliance: As of manufacturing date February 2005, all standard products meet
the requirements of 2011/65/EU, known as the RoHS initiative.
1 4
Note: Order and shipping documentation may have a -B suffix; this indicates Bulk
0.06" DIAMETER
packaging but does not show on the actual part number marked on the transformer.
HOLE
Board Layout
* Upon printing, this document is considered uncontrolled. Please contact Triad Magnetics
website for the most current version.
www.TriadMagnetics.com
460 Harley Knox Blvd.
Phone: (951) 277-0757 Publish Date: January 22, 2014
Perris, CA 92571
Fax: (951) 277-2757