Power Transformer PC Mount: Flat Pack FP56-100 Electrical Specifications ( 25C) 1. Maximum Power: 6.0 VA 2. Primary Voltage: Series: 230V 50/60 Hz Parallel: 115V 50/60Hz 3. Secondary: Series: 56.0VCT 0.100Amps Parallel: 28.0V 0.200 Amps Description: The FP56-100 is part of a series which has a long history of reliable service in the field, made from a proven design and constructed with UL recognized materials. Construction: Wound on two dual channel nylon bobbin. Materials are UL recognized, Class B (130 C) rated. 7 8 6 5 Safety: These products are 100% hipot tested with an insulation of 2000V between A primary and secondary windings and 1500V between the primary / secondary windings and the core. 34 2 1 Agency File: UL: File E53148, UL 506, Class B General Purpose Transformer, cUL: File E53148, UL 506, Class B General Purpose Transformer, Canadian Use B C Dimensions: A B C D E F D 1.875 1.562 0.875 0.267 0.375 1.600 Units: In inches Weight: 7.0 oz Pin Dimension: .020 x .041 in F Schematic: 1 5 .060 DIA HOLES 2 6 E E E 4 8 37 RoHS Compliance: As of manufacturing date February 2005, all standard products meet the requirements of 2002/95/EC, known as the RoHS initiative. * Upon printing, this document is considered uncontrolled. Please contact Triad Magnetics website for the most current version. Web: www.TriadMagnetics.com 22520B Temescal Canyon Road Phone 951-277-0757 Corona, California Publish: August 7, 2006 Fax 951-277-2757 92883