P O W E R T R A N S F O R M E R P C M O U N T : SPLIT PACK FS120-05 Description: The FS120-050 is a dual primary and dual secondary, split bobbin design which operates with either a parallel input of 115V or a series input of 230V. The output voltage will be either 120.0V with a center-tap under a 0.05A load with the secondaries wired in series, or 60.0V under a 0.1A load with the secondaries wired in parallel. The split bobbin design eliminates the need for costly electrostatic shielding. Electrical Specifications ( 25C) 1. Maximum Power: 6.0VA 2. Primary: Series: 230V Parallel: 115V 3. Secondary: Series: 120.0V CT 0.05A Parallel: 60.0V 0.1A W 4. Voltage Regulation: 25% TYP full load to no load 5. Temperature Rise: 25C TYP 6. Hipot tested 100% at 2500 VRMS Construction: Three flange bobbin construction with primaries and secondaries wound side by side for low capacitive coupling. Agency File: E UL: File E53148, UL 5085-2 (506), Class B General Purpose Transformer, cUL: File E53148, UL 5085-2 (506), Class B General Purpose Transformer, Canadian Use (CSA 22.2, No.66.2-06) L Dimensions: Units in inches. H W L A B C D E F H 1.312 1.312 1.625 0.250 0.350 1.280 0.041 0.020 0.234 Weight: 0.44 lbs 12 3 4 Schematic: D PARALLEL SERIES F 1 5 1 1 115/230V 2 6 115/230V 2 115/230V 2 A A 50/60Hz 3 7 50/60Hz 3 50/60Hz 3 58 48 4 4 B C RoHS Compliance: As of manufacturing date February 2005, all standard products meet the requirements of 2002/95/EC, known as the RoHS initiative. 1 4 As of April 7, 2008, UL standards 506 and 1585 will be migrated to UL 5085-2 0.06 DIAMETER and 5085-3, respectably. HOLE Board Layout * Upon printing, this document is considered uncontrolled. Please contact Triad Magnetics website for the most current version. Web: www.TriadMagnetics.com 22520B Temescal Canyon Road Phone 951-277-0757 Corona, California Publish Date: April 11, 2008 Fax 951-277-2757 92883