Highlights
5.8kW Single-Phase Metered PDU, 208/240V Outlets
Ideal for server rooms, network
(8 C19 and 40 C13), L6-30P, 10 ft. Cord, 0U Vertical,
closets and data centers
TAA, 70 in.
Dual load banks with 24 outlets
each (4 C19 and 20 C13)
MODEL NUMBER: PDUMV30HV2
Dedicated 20A circuit breakers
protect output
NEMA L6-30P input plug with
10-ft. (3 m) cord
Ready for immediate toolless 0U
installation
Package Includes
PDUMV30HV2 30A 208/240V
5.8kW Single-Phase Metered
PDU
Plug-lock inserts (8 C20, 40 C13)
Spare installation buttons, 2.9
mm/4.6 mm
Ground screw
Description
Mounting hardware
The 70-inch (178-centimeter) PDUMV30HV2 30A 208/240V 5.8kW Single-Phase Metered Power Distribution
Owners Manual
Unit features 48 outlets for distributing single-phase AC power to rack-mounted equipment, including computers,
routers, switches and servers.
Outlets are arranged in two separate load banks, each with 24 outlets (4 C19 and 20 C13), a dedicated 20A circuit breaker and a digital meter that reports the
banks real-time output current in amps. The ammeters let you visually monitor each bank and maintain balanced loads to prevent circuit overloads and
downtime due to breakers tripping. Special guards prevent the breakers from tripping accidentally. Outlets, breakers and ammeters are color-coded and
labeled for easy identification.
An ideal PDU for server rooms, network closets and data centers, the PDUMV30HV2s all-metal housing comes ready to mount vertically in your rack using the
preinstalled 9 mm buttons or the included hardware. The NEMA L6-30P input plug with 10-foot (3-meter) cord connects to your facilitys compatible AC power
source, generator or protected UPS. Included C20 and C14 plug-lock inserts connect to your components plugs to ensure they remain connected and
continuously powered. Use the included ground screw to connect any equipment that requires a chassis ground.
Features
Digital Meters Help Prevent Overloads
Dual digital ammeters report real-time output current in amps
Visual monitoring of PDU load level prevents overloading as more equipment is connected
Distributes Plenty of Single-Phase Power
30A 208/240V 5.8kW metered PDU (agency derated to 24A continuous)
Dual load banks with separate 20A circuit breakers and digital ammeters
48 outlets24 per bank (4 C19 and 20 C13)distribute single-phase power to connected equipment
Special guards prevent breakers from accidentally tripping
1 / 3
Each bank is color-coded and labeled for convenient identification
Connects to AC Power Source
NEMA L6-30P input plug with 10 ft. (3 m) cord for easy connection to main power source, generator or protected UPS
Included plug-lock inserts ensure components remain connected and powered
Included ground screw for equipment requiring chassis ground
Easy to Mount With or Without Tools
Ready for immediate toolless 0U installation using preinstalled 9 mm mounting buttons (spare 2.9 mm and 4.6 mm buttons included)
Nut-and-bolt vertical installation possible with included mounting hardware
Use included PDUMVROTATEBRKT mounting accessory for installation with outlets facing rear
TAA-Compliant
Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases
Specifications
OVERVIEW
PDU Type Metered
OUTPUT
5.8kW (240V), 5kW (208V), 4.8kW (200V) total capacity / 30A max (Agency de-rated to 24A), 20A max per
Output Capacity Details
breakered outlet bank; 16A max per C19 outlet; 12A max per C13 outlet
Frequency Compatibility 50 / 60 Hz
Output Receptacles (40) C13; (8) C19
Output Nominal Voltage 200; 208; 240
Overload Protection Two 20A breakers protect 24 outlets each
INPUT
PDU Input Voltage 200; 208; 240
Recommended Electrical Service 30A 208/240V
Maximum Input Amps 30
Maximum Input Amps Details Agency de-rated to 24A continuous
PDU Plug Type NEMA L6-30P
Input Cord Length (ft.) 10
Input Cord Length (m) 3.05
Input Phase Single-Phase