Magnetics Make Possible Axially Leaded Miniature Power Inductors Model HM51 Features and Benefits Electrical / Environmental HM51 Inductance Range 3.9H to 10,000H Axially Leaded Miniature Power Inductors Standard Tolerance 10% Inductance Range 3.9H to 10,000H StandardOpera Tting Tolerance emperature Range -55C to +105C10% Operating Temperature Range -55C to +105C RoHS Compliant Outline Dimensions (Inch / mm) Outline Dimensions (Inch / mm) Max. Specification 25C Specifications 25C Inductance DC Rated INCR Inductance DC Rated INCR Inductance DC Rated INCR Inductance DC Rated INCR Part Part (1) (2) (3) (1) (2) (3) Nominal Resistance IDC IDC Nominal Resistance IDC IDC (1) (2) (3) (1) (2) (3) PartNumber Nominal Resistance IDC IDC Part NumberNominal Resistance IDC IDC H 10% Max. Amps Amps H 10% Max. Amps Amps Number H 10% W Max. Amps Amps Number H 10% W Max. Amps Amps HM51-3R9KLF 3.9 0.007 8.40 15.5 HM51-221KLF 220 0.162 1.76 1.89 HM51-3R9KLF 3.9 .007 8.40 15.5 HM51-221KLF 220 .162 1.76 1.89 HM51-4R7KLF 4.7 0.008 7.90 13.9 HM51-271KLF 270 0.208 1.55 1.63 HM51-4R7KLFHM51-5R6KLF 4.7 5.6 .0080.011 7.90 6.70 13.9 12.6HM51-271KLFHM51-331KLF 270 330 .208 0.212 1.55 1.531.63 1.51 HM51-6R8KLF 6.8 0.011 6.70 11.6 HM51-391KLF 390 0.281 1.33 1.39 HM51-5R6KLF 5.6 .011 6.70 12.6 HM51-331KLF 330 .212 1.53 1.51 HM51-8R2KLF 8.2 0.013 6.20 9.89 HM51-471KLF 470 0.38 1.15 1.24 HM51-6R8KLF 6.8 .011 6.70 11.6 HM51-391KLF 390 .281 1.33 1.39 HM51-100KLF 10 0.017 5.40 8.70 HM51-561KLF 560 0.42 1.10 1.17 HM51-8R2KLF 8.2 .013 6.20 9.89 HM51-471KLF 470 .380 1.15 1.24 HM51-120KLF 12 0.019 5.10 8.21 HM51-681KLF 680 0.548 0.96 1.05 HM51-100KLF 10 .017 5.40 8.70 HM51-561KLF 560 .420 1.10 1.17 HM51-150KLF 15 0.022 4.70 7.34 HM51-821KLF 820 0.655 0.87 0.97 HM51-180KLF 18 0.023 4.70 6.64 HM51-102KLF 1,000 0.844 0.77 0.87 HM51-120KLF 12 .019 5.10 8.21 HM51-681KLF 680 .548 0.96 1.05 HM51-220KLF 22 0.026 4.40 6.07 HM51-122KLF 1,200 1.04 0.70 0.79 HM51-150KLF 15 .022 4.70 7.34 HM51-821KLF 820 .655 0.87 0.97 HM51-270KLF 27 0.027 4.30 5.36 HM51-152KLF 1,500 1.18 0.65 0.7 HM51-180KLF 18 .023 4.70 6.64 HM51-102KLF 1,000 .844 0.77 0.87 HM51-330KLF 33 0.032 4.00 4.82 HM51-182KLF 1,800 1.56 0.57 0.64 HM51-220KLF 22 .026 4.40 6.07 HM51-122KLF 1,200 1.04 0.70 0.79 HM51-390KLF 39 0.033 3.90 4.36 HM51-222KLF 2,200 2.00 0.50 0.58 HM51-470KLF 47 0.035 3.80 3.98 HM51-272KLF 2,700 2.06 0.50 0.53 HM51-270KLF 27 .027 4.30 5.36 HM51-152KLF 1,500 1.18 0.65 0.70 HM51-560KLF 56 0.037 3.70 3.66 HM51-332KLF 3,300 2.63 0.44 0.47 HM51-330KLF 33 .032 4.00 4.82 HM51-182KLF 1,800 1.56 0.57 0.64 HM51-680KLF 68 0.047 3.30 3.31 HM51-392KLF 3,900 2.75 0.43 0.43 HM51-390KLF 39 .033 3.90 4.36 HM51-222KLF 2,200 2.00 0.50 0.58 HM51-820KLF 82 0.06 2.90 3.10 HM51-472KLF 4,700 3.19 0.40 0.39 HM51-470KLF 47 .035 3.80 3.98 HM51-272KLF 2,700 2.06 0.50 0.53 HM51-101KLF 100 0.09 2.30 2.79 HM51-562KLF 5,600 3.92 0.36 0.359 HM51-560KLF 56 .037 3.70 3.66 HM51-332KLF 3,300 2.63 0.44 0.47 HM51-121KLF 120 0.113 2.10 2.54 HM51-682KLF 6,800 5.69 0.30 0.322 HM51-151KLF 150 0.129 2.00 2.22 HM51-822KLF 8,200 6.32 0.28 0.293 HM51-680KLF 68 .047 3.30 3.31 HM51-392KLF 3,900 2.75 0.43 0.43 HM51-181KLF 180 0.15 1.80 1.98 HM51-103KLF 10,000 7.30 0.26 0.266 HM51-820KLF 82 .060 2.90 3.10 HM51-472KLF 4,700 3.19 0.40 0.39 HM51-101KLFNotes:(1) Inductance is measur 100 ed at 1kHz without DC curr.090 ent.2.30 2.79 HM51-562KLF 5,600 3.92 0.36 0.359 (2) The rated DC current is based on an approximate 20C temperature rise. HM51-121KLF 120 .113 2.10 2.54 HM51-682KLF 6,800 5.69 0.30 0.322 (3) The incremental current (INCR I) is the approximate current at which the inductance will be decreased by 5% from its initial (zero DC) value due to saturation. HM51-151KLF 150 .129 2.00 2.22 HM51-822KLF 8,200 6.32 0.28 0.293 HM51-181KLF 180 .150 1.80 1.98 HM51-103KLF 10,000 7.30 0.26 0.266 Packaging Ordering Information Notes: (1) Inductance is measured at 1kHz without DC current. (2) The rated DC current is based on an approximate 20C temperature rise. HM51 - 330 K LF (3) The incremental current (INCR I) is the approximate current at which the inductance will be decreased by 5% from its initial (zero DC) value Boxes due to saturation. Model Series Lead-Free StandarPackagingd Ordering Information Inductance Code: Inductance Tolerance: First 2 digits are significant. Last digit denotes HM51 - 330 K LF J = 5% Capacity = 800Units the number of trailing zeros. For values below K = 10% 10H, R denotes the decimal point. Standard: Boxes M = 20% Model Series Lead Free Capacity = 800 Units Inductance Code: Inductance Tolerance: General Note First 2 digits are significant. Last digit denotes J = 5% TT Electronics reserves the right to make changes in product specification without notice or liability. the number of trailing zeros. For values below K = 10% All information is subject to TT Electronics own data and is considered accurate at time of going to print. www.electrtt onicsmagnecs.cti om 10H, R denotes the decimal point. M = 20% TT Electronics plc Rev. 01 35 2009/10 EDITION MAGNETIC COMPONENTS SELECTOR GUIDE We reserve the right to change specifications without prior notice. www.bitechnologies.com RoHS CompliantX-ON Electronics Largest Supplier of Electrical and Electronic Components Click to view similar products for Fixed Inductors category: Click to view products by TT Electronics manufacturer: Other Similar products are found below : CR43NP-680KC CR54NP-820KC CR54NP-8R5MC CTX32CT-100 70F224AI MGDQ4-00004-P MHL1ECTTP18NJ MHL1JCTTD12NJ PE-51506NL PE-53601NL PE-53602NL PE-53630NL PE-53824SNLT PE-62892NL PE-92100NL PG0434.801NLT PG0936.113NLT 9310-16 PM06-2N7 PM06-39NJ A01TK 1206CS-471XJ HC2-2R2TR HC2LP-R47-R HC3-2R2-R 1206CS-151XG RCH664NP-140L RCH664NP-4R7M RCH8011NP-221L RCP1317NP-332L RCP1317NP-391L RCR1010NP-470M RCR110DNP-331L DH2280-4R7M DS1608C-106 ASPI-4020HI-R10M-T B10TJ B82477P4333M B82498B3101J000 B82498B3680J000 ELJ-RE27NJF2 1812CS-153XJ 1812CS-183XJ 1812CS-223XJ 1812LS-104XJ 1812LS-105XJ 1812LS-124XJ 1812LS-154XJ 1812LS-223XJ 1812LS-224XJ