Dimming Control
High Efficiency (Up to 93%)
Active Power Factor Correction
Constant Current
Up to 305VAC Operation
Waterproof to IP67
Lightning Protection
Comprehensive Protection Circuitry
UL8750, UL1012, CSA22.2 No 107.1 & EN61347
Approvals
SELV
Electrical Specifications
Input
General
Efficiency See tables
Input Voltage 90-305VAC
MTBF (MIL-HDBK-217F) 284kHrs @120VAC, 80% load, 25C
Input Frequency 47-63 Hz
Dimensions 7.83L x 2.66W x 1.56H
Input Current
1.8A @ 100VAC Net Weight
2.20 lbs.
0.9A @ 220VAC
Inrush Current 75A @ 220VAC/25C/Cold Start
Power Factor See table
Leakage Current 1mA @ 277VAC/60Hz
THD
20% maximum
Environmental
Operating Temp. Ambient -40C to +70C,
Operating Humidity 10% to 100% RH, non-condensing
Storage Temperature -40C to +90C
Operating Temperature Case
-40C to +90C
Output
Safety & EMC
Output Voltage See table
Start Up Delay 2 seconds maximum at 110VAC/220VAC
Safety Approvals
Line Regulation 1%
USA
UL8750 Approved
Load Regulation 3%
UL1012
Ripple & Noise
10%Io typical pk-pk,
Canada
CSA-C22.2 No. 107.1,
Short Circuit No damage to unit; auto recovery when
Europe EN61347-1, EN61347-2-13
Protection fault removed
EMI
EN55015 (Radiated & Conducted), FCC
Overtemperature
Decrease output current mode. When the
Part 15 Class B
Protection case temperature reaches 120+/- 10C,
Harmonic Currents EN61000-3-2
the output current decreases to 50%Io until
Voltage Flicker
EN61000-3-3
the case temperature reaches 75C
ESD Immunity EN61000-4-2; 8kV air; 4kV contact
Radiated Immunity
EN61000-4-3
EFT/Burst
EN61000-4-4
Surge Immunity EN61000-4-5; (4kV line-line; 6kV line-gnd)
Conducted Immunity
EN61000-4-6
Magnetic Field
EN61000-4-8
Note: All specifications typical at 25C unless noted.
Dips / Interruptions EN61000-4-11
EMI Immunity Lighting
EN61547
Your Partners in Power...
Power Partners, Inc. | 43 Broad Street | Hudson, MA 01749
Tel: (978)567-9600 | Fax: (978)567-9601
Specifications subject to change.
PIL150BU-C-DT 8/19/2014
Website: www.powerpartners-inc.com
LED PowerModels and Ratings Chart
Note 1: Measured at 220VAC input and full load.
Note 2: Additional suffix may be included to denote variations or modifications to the base product.
Derating Curve
Your Partners in Power...
Power Partners, Inc. | 43 Broad Street | Hudson, MA 01749
Tel: (978)567-9600 | Fax: (978)567-9601
Specifications subject to change.
PIL150BU-C-DT 8/19/2014
Website: www.powerpartners-inc.com
LED Power