240-270 WATT ITE POWER SUPPLIES
DESCRIPTION PUP270 SERIES
RoHS
The PUP270 series of AC/DC switching power supplies are for
240-270 watts of continuous output power. They are enclosed in a
94V-0 rated plastic cases an IEC320/C14 inlet to mate with
interchangeable cord for world-wide use. All models meet EN 55022,
EN55024 and FCC class B emission limits, and comply with UL, CSA,
IEC and CE requirements.
FEATURES
SAFETY STANDARD APPROVALS
l No load power consumption less than 0. 15W
l Compliant with DoE level VI / CoC EPS V5 tier
UL 60950 3 rd, CSA C22.2 NO. 60950 3 rd
2 requirements File No. E190414
l Meet energy star EPS2.0 /ErP lot 7
l W ith PFC circuit
TV EN 60950-1
l Operating altitude up to 5000 meters
l W ide input range 90 to 264 VAC
l 100% burn-in
l Overvoltage prot ection (lat ch)
l Overcurrent protection
l Over temperature protection (latch)
l Compliant with RoHS requirements
INPUT SPECIFICATIONS
GENERAL SPECIFICATIONS
Input voltage: 90-264 VAC
Power factor: 0.98 Typical at 115 VAC
Input frequency: 47-63 Hz
Efficiency: 89% min. at full load
Input current: 3.0 A (rms) for 115 VAC
Hold-up time: 10 ms minimum at 100 VAC
1.5 A (rms) for 230 VAC
Line regulation: 0.5% maximum at full load
Earth leakage current: 3.5 mA max. @ 264 VAC, 63 Hz
Inrush current: 90 A @ 115 VAC or 180 A @ 230 VAC, at
Touch current: 100 A max. @ 264 VAC, 63 Hz
25 cold start
Withstand voltage: 1500 VAC from input to output
MTBF: 300,000 hours at full load at 25ambient ,
calculated per SR332
OUTPUT SPECIFICATIONS
Output voltage /current: See rating chart.
Maximum output power: See rating chart.
EMC Performance
Ripple and noise: See rating chart.
EN55022: Class B conducted, class B radiated
Overvoltage protection: Provided and set at 110-140% of its
nominal output voltage FCC: Class B conducted, class B radiated
Overcurrent protection: Protected to short circuit conditions
VCCI: Class B conducted, class B radiated
EN61000-3-2: Harmonic distortion, Class D
Temperature coefficient: 0.04% / maximum
Transient response: Maximum excursion of 4% or better on EN61000-3-3: Line flicker
all models, recovering to 1% of final
EN55024:
value within 500 us after a 25% step
EN61000-4-2: ESD, 15 KV air and 8 KV contact
load change
EN61000-4-3: Radiated immunity, 3 V/m
EN61000-4-4: Fast transient/burst, 1 KV
EN61000-4-5: Surge, 1 KV diff., 2 KV com.
EN61000-4-6: Conducted immunity, 3 Vrms
ENVIRONMENTAL SPECIFICATIONS
EN61000-4-8: Magnetic field immunity, 1 A/m
Operating temperature: 0 to +60
EN61000-4-11: Voltage dip immunity, 30% reduction for 500
Storage temperature: -20 to +80
ms, and >95% reduction for 10 ms
Relative humidity: 10% to 90% non-condensing
Temperature derating: Derate from 100% at +40 linearly to
50% at +60
XXUNIVERSAL INPUT
PUP270 ITE SERIES
OUTPUT VOLTAGE/CURRENT RATING CHART
Output
Min. Max. Ripple & Max. Average Active Efficiency
(1)
Model V1 Current Current Tol. Noise Power (typical) @ 115 / 230 Vac
PUP270-12-S 12 V 0 A 20.00 A 5% 240 mV 240 W 89 /89%
PUP270-13-2-S 19 V 0 A 14.21 A 5% 300 mV 270 W 89 /89%
PUP270-14-S 24 V 0 A 11.25A 5% 300 mV 270 W 89 /89%
PUP270-18-S 48 V 0 A 5.62 A 5% 500 mV 270 W 89 /89%
PUP270-19-S 54 V 0 A 5.00 A 5% 550 mV 270 W 89 /89%
NOTES:
1. Ripple and noise is maximum peak to peak voltage value measured at output within 20 MHz bandwidth, at rated line voltage
and output load ranges, and with a 47 F electrolytic capacitor in parallel with a 0.1 F ceramic capacitor across the output.
MECHANICAL SPECIFICATIONS
NOTES:
1. Dimensions shown in inches [mm]
2. Tolerance 0.02 [0.5] maximum
3. Weight: 1100 grams (2.425 lbs.) approx.
4. Output connector is JWT Mini - Fit receptacle, P/N: C4202H00-2x3P with female terminal C4202T2*-2 or equivalent, mating with JWT socket
C4201H0*-2x3P and male terminal C4201T2*-2 or equivalent. It also mates with JWT headers C4201WR*-2x3P, C4201WV*-2x3P, or equivalent.
5. V1 return (-) is electrical connected to incoming Earth Ground through two 1.2K ohm resistors as standard.
OUTPUT POWER DERATING CURVE PIN CHART
PIN 1 2 3 4 5 6
V1 V1 V1
+V1 +V1 +V1
Return Return Return
XX