Inclinometer B1N360V-Q20L60-2LU3-H1151 Rectangular, plastic, PC Compact housing Connection via M12 1 male Response time 0.1 s 1030 VDC Two counter-running 0.1 4.9 V ana- log outputs improve machine safety through redundancy Wiring Diagram Type designation B1N360V-Q20L60-2LU3-H1151 Ident-No. 1534069 Ident-No (TUSA) M1534069 Functional principle Measuring range 0360 The TURCK inclinometers incorporate a mi- Mounting conditions Vertical cromechanical pendulum, operating on the Repeatability 0.2 % of measuring range A - B Linearity deviation 0.6 % principle of MEMS technology (Mikro Elektro Temperature drift 0.05 % / K Mechanic Systems). Resolution 0.14 The pendulum basically consists of two plate Ambient temperature -30+70 C electrodes arranged in parallel with a dielec- tric placed in the middle. When the sensor is Operating voltage 1030 VDC inclined, the dielectric in the middle moves, Isolation test voltage 0.5 kV causing the capacitance ratio between both Short-circuit protection yes electrodes to change. Wire breakage/Reverse polarity protection yes/ Complete Output function 5-pin, Analog output The downstream electronics evaluates this Voltage output 0.14.9V change in capacitance and generates a corre- 2 outputs, one for CW and one for CCW sponding output signal. Load resistance voltage output 40 k Response time 0.1 s Time for the output signal to reach 90% of the ad- justed measuring range Current consumption 50105 mA (voltage-dependent) Design Rectangular, Q20L60 Dimensions 60 x 30 x 20 mm Housing material Plastic, PC Electrical connection Connector, M12 1 Vibration resistance 55 Hz (1 mm) Shock resistance 30 g (11 ms) Protection class IP68/IP69K MTTF 203 years acc. to SN 29500 (Ed. 99) 40 C 1 / 3 TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441-2656 Phone: 763-553-7300 Application Support: 1-800-544-7769 Fax 763-553-0708 www.turck.com Edition 2017-09-15T03:56:50+02:00Inclinometer B1N360V-Q20L60-2LU3-H1151 Mounting instructions/Description Tilt angle Adjusting the measuring range via TX1-Q20L60 teach adapter Setting the angular range in CW direction: Move sensor to start position Press and hold Teach-Gnd until the output is set to 0.1 V (approx. 1 s) Move sensor to end position Press and hold Teach-Gnd until the output is set to 4.9 V (approx. 3 s) Resetting the angular range: Press and hold Teach-Gnd until the output is set to 2.5 V (approx. 6 s) Angle measurement is set back to 360 degrees (in mounting positionconnector outgoing topward the sensor provides an output signal in accordance with 0 degrees) 2 / 3 TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441-2656 Phone: 763-553-7300 Application Support: 1-800-544-7769 Fax 763-553-0708 www.turck.com Edition 2017-09-15T03:56:50+02:00