ER14505: AA Size Bobbin Cell Technical Datasheet Technical Specifications 1 Part No. ER14505 (UHE-ER14505-X) Cell Type Primary, non-rechargeable Chemistry Lithium Thionyl Chloride Voltage Range 2.0V to 3.7V Nominal Voltage 3.6V Nominal Capacity 2.4Ah 1.0mA to 2.0V 23C Max. Continuous Discharge Current 100mA Max. Pulse Discharge Current 200mA Weight 19g Operating Temperature -55C to 70C 70C to 85C (max of 24 hours) Features 2 Storage Temperature -55C to 70C High and stable operating voltage 70C to 85C (max of 24 hours) Higher power and higher energy for the Terminals/Connector Flat Ni-plated end caps whole battery life Superior drain capability Safety Certified to UL1642 Higher power applications Material Safety Datasheet - MSDS095 Low self-discharge rate (less than 1% after 1 Safety Guide UBM-5135 year of storage at +20C) 3 Transportation Excepted from regulations for packages with Battery life higher than 10 years, gross mass of 2.5kg or less. depending on the application Quality Assurance Ultralife manufacturing facilities are ISO Hermetic glass-to-metal sealing 9001:2008 and ISO 14001:2004 registered. Avoid leakage, key for a higher than Its products are listed under the Component 10 year battery life Recognition Program of Underwriters Non-flammable electrolyte Safer operation in case of abuse Laboratories (UL) and have passed UN transportation testing, which is required for international transportation of all lithium Typical Applications batteries. Utility metering devices & systems Alarm and security systems Notes 1. Order by suffix, (-S) available in standard bulk as shown. Contact Ultralife for other terminal options. Machine to Machine (M2M) communications 2. Cells should be stored in temperatures less than 30C for a shelf-life of greater than five years. Automatic meter readers (AMR) 3. A complete description of transportation regulations, lithium weights and transportation classifications is Memory back-up available on the Ultralife website. Automotive electronics / telematics Industrial electronics Military and other radio applications Ultra low power devices Sonobuoys GPS tracking / mobile asset tracking ER14505 Newark, New York +1 315-332-7100 Fax: +1 315-331-7800 2017 Ultralife Corporation www.ultralifecorp.com All specific subject to change without notice. The information contained herein is for reference only and does not constitute a warrant of performance. 14 NOV 17 UBM-05290 Rev: DDimensions Typical Performance Graphs Constant Load Discharge Voltage versus Discharge Time at 25C Voltage versus Temperature at Different Discharge Currents ER14505 ER14505 3.8 3.8 3.7 3.6 3.6 3.4 3.5 3.2 3.4 10A 3.0 0.2mA 3.3 1mA 33-100mA-0.8Ah-8h 2.8 3.2 5mA 100-33mA-1.3Ah-40h 3.1 2.6 330-10mA-1.9Ah-190h 3.0 3.5k -1mA-2.4Ah-2400h 2.4 18k -0.2mA-2.3Ah-11500h 2.9 2.2 2.8 2.0 Temperature (C) Discharge Time (h) High and flat voltage at high and low drain High voltage at high drain even at -30C ER14505 Newark, New York +1 315-332-7100 Fax: +1 315-331-7800 2017 Ultralife Corporation www.ultralifecorp.com All specific subject to change without notice. The information contained herein is for reference only and does not constitute a warrant of performance. 14 NOV 17 UBM-05290 Rev: D Discharge Voltage (V) 1 10 100 1000 10000 Discharge Voltage (V) -60 -40 -20 0 20 40 60 80