CSR CSR/604/1004/1504 X10203 POWER REGULATOR CHIP INTRODUCTION The CSR Power Regulator chip is a compact and robust unit, which is capable of controlling single- phase mains driven loads of up to 15 amps. Used in conjunction with variable resistance (potentiometer), the chip gives a fully adjustable output from zero to maximum voltage. APPLICATIONS Suitable for conventional resistive heating elements such as ovens, quartz lamps, moulders and dryers. Also suitable for many inductive loads such as, transformers, fans and motors. FEATURES Available in 6, 10, and 15 ampere rating. Flexibility of mounting. Easy installation (3 pin connections). Isolated Tab. Low cost. INSTALLATIONINSTALLATION SPECIFICATIONS UNIT CSR CSR CSR CSR CSR CSR 604A 604B 1004A 1004B 1504A 1504B RMS max. On state current A 6 6 10 10 15 15 Peak one cycle surge current A 100 100 120 120 150 150 Maximum off leakage current MA ---------------------------------- 2 ---------------------------------- Minimum holding load current MA ---------------------------------- 30 --------------------------------- RMS input voltage +/- 10% 50/60 Hz V ------------------------------ 110/230 ---------------------------- Repetitive peak voltage V --------------------------------- 400 ------------------------------- Total conduction phase angle (typical) Degrees ------------------------------ 0 to 160 ---------------------------- Controlled phase angle (typical) Degrees ----------------------------- 30 to 160 ---------------------------- Power transfer at max. Current (efficiency) % ------------------------------- 99 --------------------------------- Tab surface operating range C ---------------------------- 0 to + 70 ------------------------------ Storage temperature C ---------------------------- 0 to + 75 ------------------------------ Insulation withstand capability V -------------------------- 1500 for 1 min. -------------------------- 2 2 I t limiting values for fusing As 18185050 100 100 FUSING It is recommended to use semiconductor (fast acting) type fuses or circuit breakers (Semiconductor-MCB) for protection. On initial switch on some loads may need an increased Factor of Safety (F of S) for Unit and/or Device protection. See SRA Data sheet for further information. CE MARKING This family carries a CE marking. These phase angle controllers need a suitable remote filter. For more information see recommendations section and contact our sales desk. (See Declaration of Conformity) RECOMMENDATIONS Other documents available on request, which may be appropriate for your application: - CODE IDENTITY DESCRIPTION X10229 RFI Single Phase Filtering recommendations - addressing EMC Directive X10213 ITA Interaction, uses for phase angle and for burst fire control. X10255 SRA Safety requirements - addressing the Low Voltage Directive (LVD) including: - Thermal data/cooling Live parts warning & Earth requirements Fusing recommendations. AP02/4 COS UAL Conditions of sale. NOTE It is recommended that installation and maintenance of this equipment should be done with reference to the current edition of the I.E.E. wiring regulations (BS7671) by suitably qualified/trained personnel. The regulations contain important requirements regarding safety of electrical equipment (For International Standards refer to I.E.C/ directive IEC 950). ORDER CODE: State part number: CSR A OR B + (Load rating) and (Supply voltage) Optional extras include: Knob, Dial, Heatsink compound. UNITED AUTOMATION LIMITED 1Southport Business Park Tel: 0044 (0) 1704 516500 Main Kew Tel: 0044 (0) 1704 516516 Sales Southport, PR8 4HQ Fax: 0044 (0) 1704 516501 ENGLAND Enquiry united-automation.com 2q Page No. 2 of 2 Issue 2 Date 26/04/01