M14CC8xxD108N2L Description: 7300 Lumen Linear LED Module For Use in Class 2 lighting systems Dual row LED Suitable for DLC Highbay Applications Lumen Performance: Nominal (2) Part Number Initial CRI Current Power Vf Lm/W (1) (Amps) (Watts) Lumens (Volts) 1.400 7350 35.9 50.3 146 1.150 6160 35.1 40.4 153 M14CC840D108N2L >82 1.050 5665 34.8 36.5 155 0.750 4140 33.7 25.3 164 (1) MID Flux Bin Values are shown for CCT of 4000K. Tolerance of 10% at 65C (2) Vf is at Tc of 65C with max tolerance of +/- 5%. 22.05 Mechanical Dimensions General Performance Specifications Length: 2 2 .05 Lumen Maintenance : L90 50Khrs, t =90C C Width 1 .57 Color Consistency: <3 SDCM Part Number Options Part Number CCT Lumen Multiplier Application: M14CC830D108N2L 3000K 96.8% Min. Ambient Operating Temp.: -22F, -30C M14CC835D108N2L 3500K 97.2% Max. Board Temp. (at t ): 194F, 90C C M14CC840D108N2L 4000K 100.0% Control Range: 100% to 1% M14CC850D108N2L 5000K 101.0% Maximum Current rating of 1.400 Amps M14CC865D108N2L 6500K 101.5% Regulatory Ordering Codes Description Qty/Ctn Recognized - UL8750 M14CC8xxD108N2L10C No Conformal Coat/Indoor Use Only 10 CAN/CSA-C22.2 No. 250.13-12 M14CC8xxD108N2L50C No Conformal Coat/Indoor Use Only 50 RoHS Compliant Conformal Coat 10 M14CC8xxD108N2LC10C Notes: M14CC8xxD108N2LC50C Conformal Coat 50 Performance data taken at Tc = 65C. Vf increases by 2% at 25C at initial turn on. Vf increases by 10% at -30C at initial turn on. Power consumption and photometric performance are Assembled in North America typical values. Lumen maintenance value is based on LM80 testing and TM-21 calculation projections. Application and operation performance specification information subject to change without notification. www.unvlt.com Page 1 of 3 December 15, 2016 1.57M14CC8xxD108N2L Photometric Distribution Color Consistency Spectral Power Distribution Relative 90 Luminous 75 Intensity 4000K 60 Legend 0-deg 45 45-deg 90-deg 0 15 30 Installation & Assembly Guidelines Mounting: This module should be mounted using a thermal adhesive. Thermal interface material is recommended to transfer heat away from the module to the fixture. LEDs should not be contacted during installation to avoid damage Wire Connector Wire connectors will accept 18AWG solid or bonded stranded wire. The connectors are located on the top side of the circuit board. To remove wire from connector, depress the indent on the top of the terminal with a pointed tool, and pull the wire. Electrostatic Sensitive Product Installation of Universal Everline LED Modules should be in a production environment that incorporate ESD protective measures. When servicing LED Luminaires, technicians should be grounded, and should avoid contact with the LEDs. Application and operation performance specification information subject to change without notification. www.unvlt.com Page 2 of 3 December 15, 2016