Item no.: T60404-N4646-X100 SPECIFICATION VACUUM SCHM ELZE K-No.: 25033 Date: 06.11.2007 100 A Current Sensor For the electronic measurement of currents: DC, AC, pulsed, mixed ..., with a galvanic Isolation between the primary circuit (high power) and the secondary circuit (electronic circuit) Customers Part no.: Page 1 of 2 Customer: Standard type Description Characteristics Applications Mainly used for stationary operation in industrial Closed loop (compensation) Excellent accuracy applications: Current Sensor with magnetic Very low offset current field probe AC variabel speed drives and servo motor Very low temperature dependency and offset drives Printed circuit board mounting current drift Static converters for for DC motor drives Casing and materials UL-listed Very low hysteresis of offset current Battery supplied applications Short response time Switched Mode Power Supplies (SMPS) Wide frequency bandwidth Power Supplies for welding applications Compact design Uninterruptable Power Supllies (UPS) Reduced offset ripple Electrical data Ratings I Primary nominal r.m.s. current 100 A PN R Measuring resistance V = 12V 10 ... 200 M C V = 15V 40400 C I Secondary nominal r.m.s. current 100 mA SN KN Turns ratio 1: 1000 Accuracy Dynamic performance data min. typ. max. Unit I Max. measuring range P,max V = 12V, R = 10 (t = 10sec) 230 A C M max V = 15V, R = 40 (t = 10sec) 180 A C M max X Accuracy IPN, TA= 25C 0.1 0.5 % L Linearity 0.1 % I Offset current I =0, T = 25C 0.04 0.1 mA 0 P A t Response time 1 s r t (I ) Delay time at di/dt = 100 A/s 200 ns P,max f Frequency bandwidth DC...200 kHz General data min. typ. max. Unit T Ambient operating temperature -40 +85 C A T Ambient storage temperature -40 +90 C S m Mass 14 g V Supply voltage 11.4 12 or 15 15.75 V C I Current consumption 18 mA C Constructed and manufactored and tested in accordance with EN 61800-5-1 (primary vs. secondary) Reinforced insulation, Insulation material group 1, Pollution degree 2 S Clearance (component without solder pad) 12 mm clear S Creepage (component without solder pad) 12 mm creep V System voltage overvoltage category 3 RMS 600 V sys V Working voltage (table 7 acc. to EN61800-5-1) work over voltage category 2 RMS 1000 V U Rated discharge voltage peak value 1225 V PD Maximal continuous and peak currents at defined temperatures Supply voltage 12 V: Supply voltage 15V: 70 C T 85 C 85 C 70 C 55 C TA 85 C 85 C 55 C A 70 A I 60 A 100 A 80 A 100 A I 50 A 75 A 100 A P P I 235 A 149 A 241 A 246 A I 182 A 130 A 184 A 186 A P,max P,max R 10 36 10 10 R 40 70 40 40 M M Date Name Isuue Amendment 81 freig.: Heu. Hrsg.: KB-E Bearb: KB-PM IA: Sn. Le released editor designer check Copying of this document, disclosing it to third parties or using the contents there for any purposes without express written authorization by use illegally forbidden Any offenders are liable to pay all relevant damages. Item no.: T60404-N4646-X100 SPECIFICATION VACUUM SCHM ELZE K-No.: 25033 Date: 06.11.2007 100 A Current Sensor For the electronic measurement of currents: DC, AC, pulsed, mixed ..., with a galvanic Isolation between the primary circuit (high power) and the secondary circuit (electronic circuit) Customers Part no.: Page 2 of 2 Customer: Standard type Mechanical outline (mm): General tolerances DIN ISO 2768-c Connections: 1 23 1...3: 0,7 x 0,7 mm Toleranz der Stiftabstnde 0,2mm 6,55 (Tolerances grid distance) 14,3 DC = Date Code F = Factory Marking: *= vorlufig (preliminary) 22,86 4646X100 5,08 F DC 36,5 27,6 F DC 8,5 12,35 0,4 0,7x0,7 4,50,5* 12,7 Schematic diagram i 1 + V 1 c + 3 I + s + RM - Ca 2 - V c M Temperature of the primary conductor should not exceed 110C Additional indications are obtainable on request. This specification is no declaration of warranty acc. BGB 443 dar. freig.: Heu. Hrsg.: KB-E Bearb: KB-PM IA: Sn. Le released editor designer check Copying of this document, disclosing it to third parties or using the contents there for any purposes without express written authorization by use illegally forbidden Any offenders are liable to pay all relevant damages.