Item No.: T60404-P4640-X151 SPECIFICATION V A C U U M S C H M E L Z E K-No.: Date: 26358 1000 A Current Sensor for 24V- Supply Voltage 17.02.2016 for electric current measurement: DC, AC, pulsed, mixed ..., with a galvanic isolation between primary circuit (high power) and secondary circuit (electronic circuit) Customer: Customer part no..: Page 1 of 6 Standard Type Electrical data I Primary nominal r.m.s. current 1000 A PN 1 R Measuring resistance 0 ... 100 M I Secondary nominal r.m.s. current 200 mA SN K Turns ratio (1): 5000 N 1 connected to sensor output, RM for IP,max see fig. 1 on page 2 Accuracy Dynamic performance data min. typ. max. Einheit 2 I Max. measuring range R = 10 T = 25C 2500 - - A P,max M A RM = 10 TA= 85C 2150 - - A X Accuracy I , T = -40 ... +85C - - 0.4 % PN A Linearity - - 0.1 % L I Offset current I =0, T = 25C - - 0.1 mA 0 P A I0H Hysteresis current - - 0.1 mA t Response time 80% of I - < 1 - s r PN t Reaction time 10% of I (di/dt = 1200 A/s) - - 1 s ra PN f Frequency bandwidth DC100 - - kHz BW 2 currents with high slew rates can be measured above I (transformer behavior) P,max General data min. typ. max. Einheit Ambient operating temperature -40 - +85 C A Ambient storage temperature -40 - +85 C S m Mass - 550 - g U Supply voltage 21.60 24 25.2 V C I Current consumption for Ip = 0A - 27 - mA C0 ICN Current consumption for IPN = 1000A - 190 - mA * s Clearance 20 - - mm clear * s Creepage 20 - - mm creep * U System voltage (determines impulse voltage acc. table 7) - - 1000 V sys RMS * U Working voltage (acc. U as limit in table 3) 1000 V AC ACL RMS - - 1500 V DC * UPD Rated discharge voltage (acc. table 24 with UPD=UACP) - - 1414 Vpeak Max. potential difference acc. to UL 508 - - 1000 V rms * Constructed and manufactored and tested in accordance with EN 61800-5-1:2007 (Pin 1 - 3 to primary opening) Reinforced insulation, Insulation material group 1, Pollution degree 2, Overvoltage category III Datum Name Index nderung 17.02.16 Ku 82 Data sheet reworked. CN-516 freig.: Berton Hrsg.: KB-E Bearb: KB-PM: KRe. Ku. released editor designer check Weitergabe sowie Vervielfltigung dieser Unterlage, Verwertung und Mitteilung ihres Inhalts Copying of this document, disclosing it to third parties or using the contents there for any nicht gestattet, soweit nicht ausdrcklich zugestanden. Zuwiderhandlungen verpflichten zu purposes without express written authorization by use illegally forbidden. Schadenersatz. Alle Rechte fr den Fall der Patenterteilung oder GM-Eintragung vorbehalten Any offenders are liable to pay all relevant damages. Item No.: T60404-P4640-X151 SPECIFICATION V A C U U M S C H M E L Z E K-No.: Date: 26358 1000 A Current Sensor for 24V- Supply Voltage 17.02.2016 for electric current measurement: DC, AC, pulsed, mixed ..., with a galvanic isolation between primary circuit (high power) and secondary circuit (electronic circuit) Customer: Customer part no..: Page 2 of 6 Standard Type Capability of the sensor for measuring max. peak currents at defined temperatures, values for supply voltage 22.80 V (24 V -5 %): 55 C 55 C 55 C 55 C 85C 85C 85C 85C A RM 1 5 20 50 1 5 20 50 I 2880A 2610A 1930A 1270A 2610A 2390A 1810A 1220A P,max Dwell time < 10min < 10min < 10min < 30min < 3min < 3min < 3min < 15min Limit curve of measurable current =f(R ) Values for supply voltage 22.80 V (24 V -5 %) P M Fig. 1: IPmax = f(Rm) A Absolute maximum conditions: < 70 C 70 C < 85 C A A I = I up to 1800 A 1200 A P P,max DC DC Stresses above these conditions may cause permanent damage. Exposure to absolute maximum rating conditions for extended periods will degrade device reliability and lifetime expectancy. Functional operation of the device at these or any other conditions beyond those specified in this specification is not permitted. freig.: Berton Hrsg.: KB-E Bearb: KB-PM: KRe. Ku. released editor designer check Weitergabe sowie Vervielfltigung dieser Unterlage, Verwertung und Mitteilung ihres Inhalts Copying of this document, disclosing it to third parties or using the contents there for any nicht gestattet, soweit nicht ausdrcklich zugestanden. Zuwiderhandlungen verpflichten zu purposes without express written authorization by use illegally forbidden. Schadenersatz. Alle Rechte fr den Fall der Patenterteilung oder GM-Eintragung vorbehalten Any offenders are liable to pay all relevant damages.