EAGLE SIGNAL brand CX200 Microprocessor Timer/Counter Electronic Timers Microprocessor based solid state timer/ counter... housed in CYCL-FLEX case 5 RECOGNIZED CERTIFIED E L T The CX200 is a microprocessor based timer/counter housed in a E SPECIFICATIONS I C standard 15 terminal CYCL-FLEX plug-in case. Time or count M T Time/Count Ranges: operation, time range, and standard or reverse start operation is E R selected by 7 miniature rocker switches located inside the unit housing. R O Time or count setpoints are entered into the unit using a sealed Sym. Maximum Minimum Count S T N membrane keypad on the front of the unit. Each digit in the setpoint is Range Setting Rate I I individually increased or decreased by pressing the appropriate keypad M C 500/Min. AC. 1 19999 Cts. 1 Ct. switch. Time or count setpoint and progress is displayed on the front of E 2 19999 Cts. 1 Ct. 5000/Min. AC R the unit by a 4 1/2 digit liquid crystal display with .5 inch digits. Time or S count subtracts from the setpoint and the output changes state at zero. 3 199.99 Sec01 Sec. Operational mode annunicators also appear in the display area on the 4 1999.9 Sec1 Sec. front of the unit. The mode annunciator flashes when the unit is timing 5 19.999 Sec001 Sec. or counting. 6 199 Min.: 59 Sec. 1 Sec. Five time ranges from 19.999 sec. to 199 hrs.: 59 min. 7 199 Hr.: 59 Min. 1 Min. Two count rates - accept and display counts from 1 to 19999 Two relay outputs - socket mounted for easy replacement Operating Voltage/Frequency: A6 - 120 VAC, 50/60 Hz B6 - 240 VAC, 50/60 Hz Two form C instantaneous contacts and two form C programmed K6 - 208 VAC, 50/60 Hz contacts Time Inhibit/Count Line Voltage/Frequency: N.O. solid state MOSFET, delayed action switch rated at 1 ampere A6 - 120 VAC 50/60 Hz continuous load current, 0-264 VAC 50/60 Hz or DC B6 - 240 VAC 50/60 Hz Ideal output for switching low level signals and high voltage loads K6 - 208 VAC 50/60 Hz due to MOSFET output s ON resistance of 0.5 ohm and very low Setting Accuracy: Time: 0.1% or 50 ms, whichever is larger (0 to 60C) OFF leakage Count: 100% Programmed outputs operate in one of four load sequences OOX, Repeat Accuracy: OXO, OOX with pulse output, and OOX pulse output with repeat Time: 0.001% of setting or 35 ms, whichever is larger (0 to 60C) cycle operation Count: 100% Standard start is defined as ON delay reset timer or counter Reset Time: 30 ms following voltage removal from simulated clutch input For standard start units, timer/counter resets on power failure (CR1) Reverse start or OFF delay units will not reset on power failure and Power on Response: 300 ms maximum after voltage applied to terminal 11 will continue cycle when power is restored Non-volatile memory data retention Operating Temperature: +32 to +140F (0 to +60C) Output Rating: Relay: 10 amp (resistive), 120 VAC Mechanical Life: 20 million operations Electrical Life: contingent upon controlled load Solid State: 1 amp, 0-264 VAC, VDC Vibration: Unit function is unaffected by 2.5G sinusoidal vibration magni- tude in both directions of the perpendicular mounting axes imposed from 10 to 100 Hz Static Discharge: Unit function is unaffected by a constant 3600 volt peak, 60 Hz discharge applied to the grounded front plate at a relative humidity of less than 25% Agency Approvals: UL Recognition E96337 CSA Certification LR26861 5.32 DANAHER SENSORS & CONTROLSCX200 TERMINAL ASSIGNMENTS TERMINALS AND WIRING DIAGRAM ON REAR OF TIMER CASE 1 CR1 2 1 CR1 2 6 5 7 B 8 * * 4 A 11 11 B B 3 8 6 12 3 3 9 7 4 4 2 CR1 9 10 5 10 1 1 AMPHERE 11 INSTANTANEOUS PROGRAMMED SOLID STATE A 12 CONTACTS CONTACTS MOSFET SWITCH *COUNT INPUT/TIME INHIBIT 5 *COUNT INPUT/TIME INHIBIT T E OL MOUNTING T E T I C A M T DRILL AND TAP FOUR L E HOLES FOR 8-32 SCREWS R (INCLUDED W/UNIT) I R O S ZN I I C N + 1.406 3.187 .062 + G (35.71) (80.95 1.57) DIA. CUTOUT 4.250 3.062 (107.95) (77.77) 1.406 (35.71) MTG. HOLE 1.406 1.406 USED FOR (35.71) (35.71) GROUNDING CASE 3.812 4.125 1.625 (96.82) (104.78) (41.27) 5.750 (146.05) ENCLOSURES ACCESSORIES Model No. NEMA Class Description Model No. Description HN308 1 Surface Mtg. with terminal block H-5331 Mounting Brackets 2 req d per timer HN364 1 Surface Mtg. without terminal block HP50-31 One Hole Mounting Ring HN370 1A Dual unit cabinet less unit cases and HP50-131 CYCL-FLEX Water-Sealed Housing toggle switch, with 9 terminal block HP50-133 Surface Mounting Adapter to use in place of brackets PDM-534 1/4 DIN Adapter Plate ORDERING INFORMATION CX2 02 A6 OUTPUT TYPE VOLTAGE & FREQUENCY Sym. Description Sym. Description 02 10 amp Relay Output A6 120 VAC, 50/60 Hz 240 VAC, 50/60 Hz 42 1 amp Solid State MOSFET B6 K6 208 VAC, 50/60 HZ 5.33 DANAHER SENSORS & CONTROLS T/C CR2 T/C CR2 T/C CR2