Line Filter P/N 30205 For use with VI-HAM 4.6 x 2.4 x 1 in (116,8 x 61,0 x 25,4 mm) Harmonic Attenuator Module Features Compatible with VI-HAM-xL and VI-HAM-xM D1 RoHS compliant C y CM MOV* DM R C D2 x P/N 30076 C y D3 Product Highlights HAM Filter P/N 30205 The VI-HAM Harmonic Attenuator C = 1.5 uF(x2)SH C = 0.01 uF, Y2 type LC = 6.9 mH LD = 0.72 mH Module requires an external filter to meet x y R = 235 K D1,2 = 1.5KE130CA D3 = 1.5KE150CA international standards for EMI/RFI emissions, and incorporates transient *MOV required external to filter to meet normal mode transient surge requirements surge protection, as outlined in the specifications below. Electrical Specifications Parameter Min Typ Max Unit Notes Operating voltage 85 264 Vac Operating frequency 47 63 Hz Operating current (see Figure 1) 6.3 A Leakage current at 264 Vac, 63 Hz 1.2 mA (Either line to earth) Transient surge 1 kV 1.2/50s pulse as per EN61000-4-5 with external MOV P/N 30076 Withstand 2 joules 0 to 360 phase angle exceeds IEC 801-5, Level B Dielectric withstand (line case) 1500 Vac Residual voltage after 1 sec. 34 V General Specifications Parameter Min Typ Max Unit Notes Weight 16 (457) oz (g) Size 2.4 x 4.6 x 1.0 in 6,1 x 11,7 x 2,54 cm Operating temperature (see Figure 1) -20 40 C Agency approvals UL, CSA, TV Note: The 30205 line filter is not hermetically sealed and therefore should not be subjected to post solder aqueous rinse. Line Filter Rev 1.2 vicorpower.com 800 735.6200 Page 1 of 2 4/2013 LINE LOADP/N 30205 Mechanical Outline and Recommended Layout Dimensions (All measurements are in inches) 90 RATED CURRENT VS AMBIENT TEMPERATURE 90 80 70 DM 80 60 50 70 40 CM 60 30 20 50 10 0 40 0.01 0.04 0.1 0.4 1 4 10 40 100 1.0 2.0 3.0 4.0 5.0 6.0 7.0 0.02 0.07 0.2 0.7 2 7 20 70 CURRENT (AMPS) FREQUENCY (MEGAHERTZ) Figure 1 Current rating vs. temperature Figure 2 Insertion loss vs. frequency Line Filter Rev 1.2 vicorpower.com 800 735.6200 Page 2 of 2 4/2013 OPERATING TEMP (DEG C) INSERTION LOSS (db)