End of Life IBC Module IB0xE120T40xx-xx S CUNRTL S C US 4:1 Intermediate Bus Converter Module: Up to 500W Output Features & Benefits Input: 36 60V Low profile: 0.38 height above DC (38 55V for IB048x) board DC Output: 12.0V at 48V Industry standard 1/8 Brick pinout DC IN Output current up to 40A Sine Amplitude Converter (SAC) Size: Output power: up to 500W * Low noise 1MHz ZVS/ZCS 2.30 x 0.9 x 0.38in 58.4 x 22.9 x 9.5mm 2250V isolation DC (1500V isolation for IB048x) DC 97.8% peak efficiency Typical Applications * For lower power applications, see 300W model IB0xxE120T32xx-xx Enterprise networks Optical access networks Product Description Storage networks The Intermediate Bus Converter (IBC) Module is a very efficient, low prolfi e, Automated test equipment isolated, fixed ratio converter for power system applications in enterprise and optical access networks. Rated at up to 360W from 36 to 60V and up to 500W from 50 to 55V , the IBC IN IN conforms to an industry standard eighth-brick footprint. Its leading efficiency enables full load operation at 55C with only 200LFM airflow. Its small cross section facilitates unimpeded airflow above and below its thin body to minimize the temperature rise of downstream components. Part Ordering Information Product Input Output Voltage Temperature Output Enable Package Pin Length Options Function Voltage (Nom.) x 10 Grade Current Logic I B 0 x x E 1 2 0 T 4 0 x x x x IB = Intermediate E = Eighth Brick T = -40C T +100C N = Negative OPERATING 00 = Open frame Bus Converter Format -40C T +125C P = Positive STORAGE 1 = 0.145 120 = (V nominal V = 48V x 10 048 = 38 55V OUT IN DC 40 = Max Rated Output Current DC 2 = 0.210 (4:1 transfer ratio) 050 = 36 60V DC 3 = 0.180 054 = 36 60V * DC * Operating transient to 75V DC IBC Module Rev 1.1 vicorpower.com Page 1 of 17 09/2016 800 927.9474End of Life IB0xxE120T40xx-xx Absolute Maximum Ratings The absolute maximum ratings below are stress ratings only. Operation at or beyond these maximum ratings can cause permanent damage to the device. Parameter Comments Min Max Unit Input voltage (+IN to IN) See Input Range Specific Characteristics for details -0.5 75 V DC Input voltage slew rate 5 V / s EN to IN -0.5 20 V DC Output voltage (+OUT to OUT) See OVP setpoint max -0.5 (see note) V DC Output current P 500W 40 A OUT 2250 Dielectric withstand (input to output) 1min V DC 1500 for IB048x Temperature -40 Operating junction Hottest semiconductor 125 C -55 Storage 125 Electrical Specifications Specifications valid at 48V , 100% rated load and 25C ambient, unless otherwise indicated. IN A t t rib u t e Symbol Conditions / Notes Min Typ Max Unit Input Range Specific Characteristics Part Number IB048E120T40xx-xx Operating input voltage 38 48 55 V DC Non-operating input surge withstand < 100ms 75 V DC Operating input dV / dt 0.003 5 V / s Undervoltage protection Turnon 33 38 V DC Turnoff 31 36 V DC Turnon / turnoff hysteresis 2 V DC Time constant 7 s Undervoltage blanking time UV blanking time is enabled after start up 50 100 200 s Overvoltage protection Turnoff 60 64 V DC Turnon 55 64 V DC Time constant 4 s Peak short circuit input current 30 A DC output voltage band No load, over V range 9.5 12.0 13.75 V IN DC Output OVP set point Module will shut down 15 16 V DC Dielctric withstand Input to output 1min 1500 V DC Insulation resistance Input to output 30 M IBC Module Rev 1.1 vicorpower.com Page 2 of 17 09/2016 800 927.9474