End of Life MIL-COTS Filter MF028AMFPT S CUNRTLS C US DC front-end module with EMI filtering & transient protection Features 55C to 100C baseplate operation Height above board: 0.37 in (9.5 mm) Vin range: 16.5 50 Vdc Low weight: 1.07 oz (30.4g) EMI filtering: MIL-STD-461E/F Typical efficiency: 99% Transient protection MIL-STD-1275 Architectural flexibility A/B/D and MIL-STD-704A/E/F Size: 1.91 x 1.09 x 0.37 in 48,6 x 27,7 x 9,5 mm Product Overview The MIL-COTS filter is a DC front-end module that provides EMI filtering and transient protection. The filter enables designers using Vicors MIL-COTS PRM , VI Bricks and VI Chips to meet conducted emission / conducted susceptibility per MIL-STD-461E and input transients per MIL-STD-704A/E/F and MIL-STD-1275A/B/D. The MIL-COTS PRM filter accepts an input voltage of 16.5 50 Vdc and delivers output power up to 120 W. Absolute Maximum Ratings Parameter Values Unit Notes +In to -In -1.0 to 60.0 Vdc Continuous +Out to -Out -1.0 to 60.0 Vdc Continuous Continuous output power 120 W Operating temperature -55 to +100 C M-Grade baseplate Storage temperature -65 to +125 C M-Grade Note: Stresses in excess of the maximum ratings can cause permanent damage to the device. Operation of the device is not implied at these or any other conditions in excess of those given in the specification. Exposure to absolute maximum ratings can adversely affect device reliability. MIL-COTS Filter Rev 1.6 vicorpower.com 800 927.9474 Page 1 of 6 06/2014End of Life MF028AMFPT SPECIFICATIONS PART NUMBERING MF 028 A M F P T Input Package VI BRICK Filter Voltage Size Designator Product Grade Temperatures (C) Baseplate Pin Style Grade Operating Storage P = Through hole F = Slotted flange a P = Pin Fin heat sink M = -55 to +100 -65 to +125 a Contact Factory (Conditions are at 28 Vin, full load, and 25C baseplate unless otherwise specified) Input Specifications Parameter Min Typ Max Unit Notes Input voltage range 16.5 28 50 Vdc Operation to 13.5 V after start up 16.5 V Input current 8 Adc Inrush limiting 0.01 A/F Recommended external input capacitance 10 F C1 Figure 7 Transient Immunity 100 Vdc 50 ms per MIL-STD-1275A/B/D continuous operation 250 Vdc 70 s per MIL-STD-1275A/B/D continuous operation 70 Vdc 20 ms per MIL-STD-704A continuous operation 80 Vdc 100 ms per D0-160 E, sec.16, Cat. z cont. operation 50 Vdc 12.5 ms per MIL-STD-704E/F continuous operation (Conditions are at 28 Vin, full load, and 25C baseplate unless otherwise specified) Output Specifications Parameter Min Typ Max Unit Note Output voltage range 16.0 28 49.6 Vdc Internal voltage drop 0.4 0.85 Vdc Output current 0 8 Adc Over input range Efficiency Full load 99 % External output capacitance 1000 F Figure 7 C IN Safety Specifications Parameter Min Typ Max Unit Note None Vrms Input / Output Dielectric withstand 707 Vdc Input / Output to Base / EMI Pin EMI Standard Test Procedure Notes MIL-STD-461E/F Conducted Emissions CE101-4 Navy ASW & Army Aircraft, Curve 2 (28 Vdc) CE102-1 Basic curve, for all applications Conducted Susceptability CS101-1 Curve 2, for all applications (28 Vdc) CS114-1 Conducted suceptibility, bulk cable injection, 10 KHz - 200 MHz, Curve 4 CS115-1 Conducted suceptibility, bulk cable injection, impulse excition, all applications MIL-COTS Filter Rev 1.6 vicorpower.com 800 927.9474 Page 2 of 6 06/2014