Maxi Family 150V Input Actual size: 4.6 x 2.2 x 0.5in S 117 x 56 x 12,7mm CUNRTL S C US DC-DC Converter Module Features & Benefits Applications Communications, control systems, medical, instrumentation, defense and aerospace. DC input range: 100 200V Isolated output For details on proper operation please refer to the: Design Guide & Applications Manual for Maxi, Mini, Micro Family. Encapsulated circuitry for shock and vibration resistance Extended temperature range Absolute Maximum Ratings (55 to +100C) Input surge withstand: 250V for 100ms Parameter Rating Unit Notes DC output: 3.3 48V +IN to IN voltage 0.5 to +260 V DC Programmable output: 10 110% PC to IN voltage 0.5 to +7.0 V DC Regulation: 0.2% no load to full load PR to IN voltage 0.5 to +7.0 V DC Efficiency: Up to 90% SC to OUT voltage 0.5 to +1.5 V DC Maximum operating temp: 100C, Sense to OUT voltage 1.0 V DC full load Isolation voltage Power density: up to 100W per cubic inch IN to OUT 3000 V Test voltage RMS Height above board: 0.43in 10,9mm IN to base 1500 V Test voltage RMS Parallelable, with N+M fault tolerance OUT to base 500 V Test voltage RMS Low-noise ZCS/ZVS architecture Operating Temperature 55 to +100 C M-Grade RoHS Compliant (with F or G pin option) Storage Temperature 65 to +125 C M-Grade 500 260 F C <5 sec wave solder Product Overview Pin soldering temperature 750 390 F C <7 sec hand solder These DC-DC converter modules use advanced Mounting torque 5 0.57 in lbs N m 6 each power processing, control and packaging technologies to provide the performance, flexibility, reliability and cost effectiveness of a mature power component. High-frequency ZCS/ZVS switching provides high power density with low noise and high efficiency. Part Numbering e.g. V150A24C500BL V150A B Product Grade Temperatures (C) Pin Style Finish Baseplate Output Power Output Voltage Blank: Slotted Grade Operating Storage V P Blank: Short Tin/Lead OUT OUT 3V3 = 3.3V 2: Threaded E = 10 to +100 20 to +125 3.3V 200W, 264W L: Long Tin/Lead 5 = 5V 3: Through-hole C = 20 to +100 40 to +125 5V 300W, 400W S: Short ModuMate Gold 8 = 8V T = 40 to +100 40 to +125 8V 300W, 400W N: Long ModuMate Gold 12 = 12V H = 40 to +100 55 to +125 12V 400W, 500W F: Short RoHS Gold 15 = 15V M = 55 to +100 65 to +125 15V 400W, 500W G: Long RoHS Gold 24 = 24V 24V 400W, 500W K: Extra Long RoHS Gold 28 = 28V 28V 400W, 500W 36 = 36V 36V 400W, 500W 48 = 48V 48V 400W, 500W Note: Product images may not highlight current product markings. 150V Maxi Family Rev 3.1 Page 1 of 13 02/2021150V Input Module Family Electrical Characteristics Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified. All temperatures refer to the operating temperature at the center of the baseplate. Module Input Specifications Parameter Min Typ Max Unit Notes Operating input voltage 100 150 200 V DC Input surge withstand 250 V <100ms DC Undervoltage turn-on 97.0 99.0 V DC Undervoltage turn-off 81.9 84.9 V DC Overvoltage turn-off/on 201.9 210 220 VDC Disabled input current 1.1 mA PC pin low Module Output Specifications Parameter Min Typ Max Unit Notes Output voltage set point 1 % Of nominal output voltage. Nominal input full load 25C Line regulation 0.02 0.20 % Low line to high line full load Temperature regulation 0.002 0.005 % / C Over operating temperature range Power sharing accuracy 2 5 % 10 100% of full load Of nominal output voltage. For trimming below 90% Programming range 10 110 % of nominal, a minimum load of 10% of maximum rated power may be required. +OUT to OUT, +Sense to OUT Absolute Maximum Ratings 3.3V 0.5 to 4.7 V Externally applied DC 5V 0.5 to 7.0 V Externally applied DC 8V 0.5 to 10.9 V Externally applied DC 12V 0.5 to 16.1 V Externally applied DC 15V 0.5 to 20.0 V Externally applied DC 24V 0.5 to 31.7 V Externally applied DC 28V 0.5 to 36.9 V Externally applied DC 36V 0.5 to 47.4 V Externally applied DC 48V 0.5 to 62.9 V Externally applied DC Note: The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output related application information, please refer to output connections on page 8. Thermal Resistance and Capacity Parameter Min Typ Max Unit Baseplate to sink flat, greased surface 0.08 C/Watt Baseplate to sink thermal pad (P/N 20263) 0.07 C/Watt Baseplate to ambient 4.9 C/Watt Baseplate to ambient 1000LFM 1.1 C/Watt Thermal capacity 165 Watt-sec/C 150V Maxi Family Rev 3.1 Page 2 of 13 02/2021