Mini Family 24V Input Actual size: 2.28 x 2.2 x 0.5in S 57,9 x 55,9 x 12,7mm CUNRTL S C US DC-DC Converter Module Features & Benefits Applications DC input range: 18 36V Industrial and process control, distributed power, medical, ATE, communications, defense and aerospace. Isolated output For details on proper operation please refer to the: Operation to 16V at 75% power Design Guide & Applications Manual for Maxi, Mini, Micro Family. after start up Input surge withstand: 50V for 100ms Absolute Maximum Ratings DC output: 3.3 48V Programmable output: 10 110% Parameter Rating Unit Notes Regulation: 0.5% no load to full load +IN to IN voltage 0.5 to +53 V DC Efficiency: Up to 89% PC to IN voltage 0.5 to +7.0 V DC Maximum operating temp: 100C, PR to IN voltage 0.5 to +7.0 V DC full load SC to OUT voltage 0.5 to +1.5 V DC Power density: up to 80W per cubic inch Sense to OUT voltage 1.0 V DC Height above board: 0.43in 10,9mm Isolation voltage Parallelable, with N+M fault tolerance IN to OUT 3000 V Test voltage RMS Low-noise ZCS/ZVS architecture IN to base 1500 V Test voltage RMS RoHS Compliant (with F or G pin option) OUT to base 500 V Test voltage RMS Operating Temperature 55 to +100 C M-Grade Product Overview Storage Temperature 65 to +125 C M-Grade 500 260 F C <5sec wave solder These DC-DC converter modules use advanced Pin soldering temperature power processing, control and packaging 750 390 F C <7sec hand solder technologies to provide the performance, Mounting torque 5 0.57 in lbs N m 6 each flexibility, reliability and cost effectiveness of a mature power component. High-frequency ZCS/ZVS switching provides high power density with low noise and high efficiency. Part Numbering 24B B e.g. V24B12T200BL2 Product Grade Temperatures (C) Output Power Pin Style Finish Baseplate Output Voltage Product Type V P Blank: Slotted 3V3 = 3.3V Grade Operating Storage OUT OUT Blank: Short Tin/Lead V = Standard 5 = 5V 2: Threaded 3.3V 100W, 150W E = 10 to +100 20 to +125 L: Long Tin/Lead S = Enhanced 6.5 = 6.5V 5V 150W, 200W 3: Through-hole C = 20 to +100 40 to +125 S: Short ModuMate Gold efficiency 8 = 8V 6.5V 200W T = 40 to +100 40 to +125 N: Long ModuMate Gold (avail. 12 12 = 12V 8V 200W H = 40 to +100 55 to +125 F: Short RoHS Gold V only) OUT 15 = 15V 12V 150W, 200W, 250W M = 55 to +100 65 to +125 G: Long RoHS Gold 24 = 24V 15V 150W, 200W K: Extra Long RoHS Gold 28 = 28V 24V 150W, 200W, 250W 36 = 36V 28V 150W, 200W, 250W 48 = 48V 36V 150W, 200W 48V 150W, 200W, 250W Note: Product images may not highlight current product markings. 24V Mini Family Rev 5.4 Page 1 of 15 07/201924V Input Module Family Electrical Characteristics Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified. All temperatures refer to the operating temperature at the center of the baseplate. Module Input Specifications Parameter Min Typ Max Unit Notes Operating input voltage 18 24 36 V DC Input surge withstand 50 V <100ms DC Undervoltage turnon 17.5 17.9 V DC Undervoltage turnoff 14.8 15.3 V DC Overvoltage turnoff/on 36.3 37.8 39.6 V DC Disabled input current 4.0 V PC pin low DC Module Output Specifications Parameter Min Typ Max Unit Notes Output voltage set point 1 % Of nominal output voltage. Nominal input full load 25C Line regulation 0.02 0.20 % Low line to high line full load Temperature regulation 0.002 0.005 %/C Over operating temperature range Power sharing accuracy 2 5 % 10 100% of full load Of nominal output voltage. For trimming below 90% Programming range 10 110 % of nominal, a minimum load of 10% of maximum rated power may be required. +OUT to OUT, +Sense to OUT Absolute Maximum Ratings 3.3V 0.5 to 4.7 V Externally applied DC 5V 0.5 to 7.0 V Externally applied DC 6.5V 0.5 to 9.1 V Externally applied DC 8V 0.5 to 10.9 V Externally applied DC 12V 0.5 to 16.1 V Externally applied DC 15V 0.5 to 20.0 V Externally applied DC 24V 0.5 to 31.7 V Externally applied DC 28V 0.5 to 36.9 V Externally applied DC 36V 0.5 to 47.1 V Externally applied DC 48V 0.5 to 62.9 V Externally applied DC Note: The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output related application information, please refer to output connections on page 10. Thermal Resistance and Capacity Parameter Min Typ Max Unit Baseplate to sink flat, greased surface 0.16 C/Watt Baseplate to sink thermal pad (P/N 20264) 0.14 C/Watt Baseplate to ambient 8.0 C/Watt Baseplate to ambient 1000LFM 1.9 C/Watt Thermal capacity 83 Watt-sec/C 24V Mini Family Rev 5.4 Page 2 of 15 07/2019