Micro Family 375V Input Actual size: 2.28 x 1.45 x 0.5in S 57,9 x 36,8 x 12,7mm CUNRTL S C US DC-DC Converter Module Features & Benefits Applications Industrial and process control, distributed power, medical, ATE, communications, DC input range: 250 425V defense and aerospace. Isolated output For details on proper operation please refer to the: Input surge withstand: 500V for 100ms Design Guide & Applications Manual for Maxi, Mini, Micro Family. DC output: 2 48V Programmable output: 10 110% Absolute Maximum Ratings Regulation: 0.5% no load to full load Efficiency: Up to 88% Parameter Rating Unit Notes +IN to IN voltage 0.5 to +525 V Maximum operating temp: 100C, DC full load PC to IN voltage 0.5 to +7.0 V DC PR to IN voltage 0.5 to +7.0 V Power density: up to 90W per cubic inch DC SC to OUT voltage 0.5 to +1.5 V DC Height above board: 0.43in 10,9mm Isolation voltage Parallelable, with N+M fault tolerance IN to OUT 3000 V Test voltage RMS Low-noise ZCS/ZVS architecture IN to base 1500 V Test voltage RMS RoHS Compliant (with F or G pin option) OUT to base 500 V Test voltage RMS Operating Temperature 55 to +100 C M-Grade Product Overview Storage Temperature 65 to +125 C M-Grade 500 260 F C <5sec wave solder These DC-DC converter modules use advanced Pin soldering temperature power processing, control and packaging 750 390 F C <7sec hand solder technologies to provide the performance, Mounting torque 5 0.57 in lbs N m 6 each flexibility, reliability and cost effectiveness of a mature power component. High-frequency ZCS/ZVS switching provides high power density with low noise and high efficiency. Part Numbering e.g. V375C12T150BL2 375C B Product Grade Temperatures (C) Output Power Pin Style Finish Baseplate Output Voltage Product Type Blank: Slotted Grade Operating Storage V P Blank: Short Tin/Lead OUT OUT 2 = N/A V = Standard 2: Threaded E = 10 to +100 20 to +125 2V 50W L: Long Tin/Lead 3V3 = 3.3V S = Enhanced 3: Through-hole C = 20 to +100 40 to +125 3.3V 50W, 75W S: Short ModuMate Gold 5 = 5V efficiency T = 40 to +100 40 to +125 5V 50W, 100W N: Long ModuMate Gold 8 = 8V (avail. 12 H = 40 to +100 55 to +125 8V 100W F: Short RoHS Gold 12 = 12V V only) OUT M = 55 to +100 65 to +125 12V 75W, 150W G: Long RoHS Gold 15 = 15V 15V 75W, 150W K: Extra Long RoHS Gold 24 = 24V 24V 75W, 150W 28 = 28V 28V 75W, 150W 36 = 36V 36V 75W, 150W 48 = 48V 48V 75W, 150W Note: Product images may not highlight current product markings. 375V Micro Family Rev 9.9 Page 1 of 14 08/2019375V Input Module Family Electrical Characteristics Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified. All temperatures refer to the operating temperature at the center of the baseplate. Module Input Specifications Parameter Min Typ Max Unit Notes Operating input voltage 250 375 425 V DC Input surge withstand 500 V <100ms DC Undervoltage turn-on 242.5 247.5 V DC Undervoltage turn-off 204.7 212.2 V DC Overvoltage turn-off/on 429.2 446.3 467.5 V DC Disabled input current 1.1 mA PC pin low Module Output Specifications Parameter Min Typ Max Unit Notes Output voltage set point 1 % Of nominal output voltage. Nominal input full load 25C Line regulation 0.02 0.20 % Low line to high line full load Temperature regulation 0.002 0.005 % / C Over operating temperature range Power sharing accuracy 2 5 % 10 100% of full load Of nominal output voltage. For trimming below 90% Programming range 10 110 % of nominal, a minimum load of 10% of maximum rated power may be required. +OUT to OUT Absolute Maximum Ratings 2V 0.5 to 3.1 V Externally Applied DC 3.3V 0.5 to 4.7 V Externally Applied DC 5V 0.5 to 7.0 V Externally Applied DC 8V 0.5 to 10.9 V Externally Applied DC 12V 0.5 to 16.1 V Externally Applied DC 15V 0.5 to 20.0 V Externally Applied DC 24V 0.5 to 31.7 V Externally Applied DC 28V 0.5 to 36.9 V Externally Applied DC 36V 0.5 to 47.1 V Externally Applied DC 48V 0.5 to 62.9 V Externally Applied DC Note: The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output related application information, please refer to output connections on page 9. Thermal Resistance and Capacity Parameter Min Typ Max Unit Baseplate to sink flat, greased surface 0.24 C/Watt Baseplate to sink thermal pad (P/N 20265) 0.21 C/Watt Baseplate to ambient 10.9 C/Watt Baseplate to ambient 1000LFM 2.8 C/Watt Thermal capacity 48 Watt-sec/C 375V Micro Family Rev 9.9 Page 2 of 14 08/2019