Not Recommended for New Designs VI-HAM, VE-HAM VxHAMxM (Compatible with VI-26x and VI-J6x modules) Actual Size: S 4.6 x 2.4 x 0.5in (116,8 x 61,0 x 12,7mm) CUNRTL S C US Harmonic Attenuation Module Features & Benefits Absolute Maximum Ratings Unity power factor Parameter Rating Unit Notes 265 V Continuous AC Safety agency approvals: L to N voltage 280 V 100ms AC CE marked, cTVus, cURus Mounting torque 5 (0.57) in- lbs (N-m) 6-32 or m3.5 Meets IEC 6100-3-2 for line 750 F Current harmonic content Pin soldering temperature (400) (C) Reduces peak and RMS line currents Operating temperature 55 to +85 C M-Grade Universal input: Storage temperature 65 to +100 C M-Grade 85 264V : 50/60Hz AC Auxiliary output 3 mA Up to 600W of power Note: High Boost Ham recomended for new designs (VI-HAM-xL) 3 Power density up to 100W/in Adaptive output voltage control Short-circuit protection Part Numbering Input surge current limiting Converter enable VI - HAM - C M Power OK output Product GradeTemperatures (C) Output RoHS Designator M = 600W Grade Operating Storage Efficiency: 90-94% typical VI = Non RoHS Compliant E = 10 to +85 40 to +100 VE = RoHS Compliant C = 25 to +85 40 to +100 RoHS compliant I = 40 to +85 55 to +100 M = 55 to +85 65 to +100 Product Highlights Product Type HAM = Hamonic Attenuator Module The Harmonic Attenuator Module (HAM) HAMD = Hamonic Attenuator Module Driver BAMD = Hamonic Attenuator Module Booster accepts an input of 85 264V . It AC provides a DC output compatible with (HAMD and BAMD can be used in parallel Vicors VI-26x, VI-J6x and user-denfi ed or in arrays for applications that require more power than that available from a single HAM) Maxi, Mini and Micro DC-DC converters. The combination of a HAM, one or more Vicor DC-DC converters, and the 30205 line filter, listed on Page 8, offers a high density power solution m e e t ing EN 610 0 0 -3 -2. For application information please see the Design Guide at vicorpower.com. VI-HAM, VE-HAM Rev 2.8 Page 1 of 10 03/2020Not Recommended for New Designs VxHAMxM Electrical Characteristics Electrical characteristics apply over the specified operating voltage range, output load and baseplate temperature, unless otherwise specified. All temperatures refer to the operating temperature of the baseplate. Specifications apply for AC mains having no more than 5% total harmonic distortion. INPUT SPECIFICATIONS (HAM-xM, HAMD-xM, BAMD-xM) Parameter Min Typ Max Unit Notes Operating input voltage 85 264 V Rectified AC for HAMD, BAMD AC HAM, HAMD, BAMD Unit will operate at 400Hz but may not meet AC line frequency 47 63 Hz PF or THD specs Power factor 0.99 115/230V , 50 100% of full load AC Total harmonic distortion 7.5 % 115V , sinusoidal input, full load AC (line current) 8.5 % 230V , sinusoidal input, full load AC 20 Amps 230V , full load AC Inrush current 13 Amps 115V , full load AC CM Filter Inductance 3 6 mH External to HAM module (see Figure 10) DM Filter Inductance 0.2 0.35 0.75 mH External to HAM module (see Figure 10) OUTPUT SPECIFICATIONS Parameter Min Typ Max Unit Notes Maximum output power 600 Watts See power derating graph, Figure 3 258 260 262 V 115V IN DC AC Output voltage (See Figure 3) 360 365 370 V 230V IN DC AC 90 91 % 115V , sinusoidal input, full load AC Includes external rectifier Efficiency loss for HAMD and BAMD 93 94 % 230V , sinusoidal input, full load AC 300W, 500F minimum, external to HAM External hold up capacitance 500 3,000 F per HAM 600W, 1,000F minimum, external to HAM Ride through / hold up time 16 ms 600W output with 1,000F hold up capacitor, external to HAM 7 10 Vp-p 115V , full load, 1,000F hold up capacitor AC , external to HAM Ripple , external to HAM 5 6 Vp-p 230V , full load, 1,000F hold up capacitor AC Short circuit shut down current 100 mA Foldback current limiting CONTROL SPECIFICATIONS Parameter Min Typ Max Unit Notes Power OK threshold 230 V DC Module enable/disable 240 V DC threshold 19 23 V 3mA DC Auxiliary output 3 mA Do not overload or add external capacitance VI-HAM, VE-HAM Rev 2.8 Page 2 of 10 03/2020