ComPAC DC-DC Switchers 50 600 Watts 1 3 Outputs Features & Benefits Configuration Chart Number of RoHS Compliant (VE versions) a Configuration Output Power Dimensions Modules Inputs 24, 48 and 300V DC Single Output 8.6 x 2.5 x 0.99in Any output: 1 95V DC VILC 50 200W 1 218,4 x 63,5 x 25,2mm Meets EN55022 Class A F A 8.6 x 4.9 x 0.99in VIMC 100 400W 2 conducted emissions (See Notes) 218,4 x 124,5 x 25,2mm FFF AAA F A 8.6 x 7.3 x 0.99in cULus, cTVus (60950-1) VINC 300 600W 3 FFF AAA 218,4 x 185,4 x 25,2mm A CE marked (LVD) F Dual Output FFF AAA 8.6 x 4.9 x 0.99in 80 90% efficiency VIPC 100 400W 2 218,4 x 124,5 x 25,2mm 3 Up to 10W/in F FA A 8.6 x 7.3 x 0.99in VIQC 150 600W 3 218,4 x 185,4 x 25,2mm FF FFAA AA Overall disable F A F A Triple Output Overvoltage shut down FF FFAA AA 8.6 x 7.3 x 0.99in VIRC 150 600W 3 218,4 x 185,4 x 25,2mm a F FA FA A Substitute VE for VI for RoHScompliant versions Product Description FF FAAFFA AA Input Voltage Output Voltage ComPAC delivers up to 600W from Z = 2V 2 = 15V one, two, or three outputs in a package Input Low Line Maximum Transient Nominal Range Full 75% Max. just 0.99in 25,2mm in height with the Y = 3.3V N = 18.5V b Power (1s) Power Power fieldproven performance, high efficiency F A F A 0 = 5V 3 = 24V and high reliability inherent in Vicor 1 = 24V 21 32V (1) 18 36 X = 5.2V L = 28V component level power converters. W = 24V 18 36V (1) N/A N/A W = 5.5V J = 36V ComPAC meets conducted emissions of 3 = 48V 42 60V (2) 41 72 V = 5.8V K = 40V EN55022 Class A. ComPAC is offered with N = 48V 36 76V (2) N/A N/A T = 6.5V 4 = 48V input voltage ranges optimized for industrial 6 = 300V 200 400V (2) 188 425 and telecommunication applications and R = 7.5V H = 52V b Max Output 5V >5V <5V provides extended input overv oltage M = 10V F = 72V per Module Outputs Outputs Outputs capability, undervoltage lockout and 1 = 12V D = 85V (1) 150W 150W 30A overall disable. P = 13.8V B = 95V (2) 200W 200W 40A Product Grade Case Temps. C Output Power / Current Packaging Options Grade Operating Storage V 5V V < 5V OUT OUT F A Conduction Cooled Models Available. Y = 50W Y = 10A E = 10 to +85 20 to +100 Add CC to the end of the part number. F A (Consult factory for details.) X = 75W X = 15A C = 25 to +85 40 to +100 Extended heat sink available. W = 100W W = 20A I = 40 to +85 55 to +100 Add H1 to end of part number. V = 150W V = 30A M = 55 to +85 65 to +100 U = 200W U = 40A Output Power / Current Output Power / Current V 5V V < 5V OUT OUT A F V 5V V < 5V W = 100W W = 20A OUT OUT A F V = 150W V = 30A S = 300W S = 60A U = 200W U = 40A P = 450W P = 90A S = 300W S = 60A M = 600W M = 120A Q = 400W Q = 80A ComPAC DC-DC Rev 1.4 Page 1 of 8 11/2020ComPAC DC-DC Switchers Configurable Specifications Typical at T = 25C, nominal line and 75% load, unless otherwise specified, V is factory set output voltage and I is maximum rated output current. BP NOM NOM Input Specifications E-Grade C-, I-, M-Grade Parameter Min Typ Max Min Typ Max Unit Test Conditions 24V 21 24 32 21 24 32 V DC 24V Wide 18 24 36 18 24 36 V DC See Fusing Information 48V 42 48 60 42 48 60 V DC on Page 3 48V Wide 36 48 76 36 48 76 V DC 300V 200 300 400 200 300 400 V DC c No Load Power Dissipation 1.35 2 1.35 2 Watts Sink or source to disable optocoupler (See Section 18 c Overall Disable Input Current ComPAC Technical Description 4 4 mA (Absolute Max., 20mA) in VI200/VIJ00 Applications Manual) Quiescent Input Current Current drawn from source 7 10 7 10 mA c Logic Disable when disabled c For MC, PC series, multiply value by 2 for NC, QC, RC series, multiply value by 3. Output Specifications Applies to each output individually. E-Grade C-, I-, M-Grade Parameter Min Typ Max Min Typ Max Units Test Conditions Set Point Accuracy 1% 2% 0.5% 1% V NOM Load / Line Regulation 0.5% 0.05% 0.2% V LL to HL, 10% to full load NOM Load / Line Regulation 1% 0.2% 0.5% V LL to HL, no load to full load NOM Output Temperature Drift 0.02 0.01 0.02 %/C Overrated temperature range LongTerm Drift 0.02 0.02 %/1khrs. Output Ripple 2V, 3.3V 150 60 100 mV 20MHz bandwidth PP 5V 250 100 150 mV 20MHz bandwidth PP 10 48V 3% 0.75% 1.5% V 20MHz bandwidth NOM PP d Output Voltage Trimming 50% 110% 50% 110% V NOM Total RemoteSense 0.25V maximum allowable 0.5 0.5 Volts d Compensation drop in OUT lead OVP Set Point 125% 115% 125% 135% V Recycle power to restart NOM Current Limit 105% 135% 105% 125% I Automatic restart NOM e ShortCircuit Current 20% 140% 20% 130% I NOM d 10, 12 and 15V outputs, trim range 10%. Consult factory for wider trim range. e Output voltages of 5V or less incorporate foldback current limiting, outputs greater than 5V incorporate straight line current limiting. ComPAC DC-DC Rev 1.4 Page 2 of 8 11/2020