Do not overload the device above its nominal power. When connecting refrigerators, PURE SINE WAVE ELECTRONIC CONVERTERS WITH UPS FUNCTION freezers and other induction appliances / consuming more power on start-up, remember not to exceed 30% of the total power rating of the UPS. Do not connect the device outdoors, avoid contact of the UPS with water. sinusPRO E Remember to place the power supply in the correct place, with access to fresh air and a minimum distance of 30 cm from each side of the housing. If you notice an incorrect operation / damage to the converter, contact the manufacturer s DEVICE CHARACTERISTICS service. Functions of DC/AC converter, UPS and automatic batteries charger contained in one Verify if the device is working correctly after connecting all connected appliances, turning device off the AC Voltage using the fuse breaker, do not disconnect plug from the AC socket, Toroidal transformer used in the converter provides high efficiency and low idle current. because this way you would disconnect the fixed zero taken from the mains. The device is much more energy-efficient than older constructions using transformers The battery charger built into the sinusPRO E series converters operates on the principle of with E-type core buffer charging. We recommend using batteries adapted for buffer charging and Fast 32-bit microprocessor ensures accurate and failure-free operation deep discharge, for example: dedicated AGM VPRO, gel, acid closed DEEP CYCLE etc. Intuitive and simple operation thanks to the color LED display, which informs about the Connection car battery to the converter (acid starter) that is not adapted to such operation current device operating status (input and output voltage, battery status, charging, etc.) may result in incorrect converter operation and / or damage to the battery. The converter generates a pure sinusoidal voltage at the output, which makes it The AC output of the converter is used for direct supply of connected devices in the so- possible to work with virtually any type of load called island system. It is forbidden to connect the AC output to the existing electrical High battery charging current (exact values in the table with technical specifications) installation (even through a residual-current protection), and in particular to phase, neutral Possibility of changing the charging current using a button and switching off the N and differential-current wires. Such connection may result in reverse voltage charger applied to the converter output. Damage caused by such connection results in the Fast switching from AC supply to UPS operating mode enables uninterrupted operation of loss of the warranty connected devices Other important information related to for example: batteries selection, required power Intelligent cooling fan control, depending on the actual temperature of the device and calculation or battery pack capacity calculation can be found on our website inverter operating status www.voltpolska.pl TURNING ON UPS Model 500E 800E 1000E 1500E 3000E Open the box and check that all components are included and the device is undamaged. Total power 500VA 800VA 1000VA 1500VA 300VA Disconnect power supply cable from the device. Nominal power 300W 500W 700W 1050W 2100W Connect battery correctly to the device according to the correct polarity (red wire + / black Idle current (battery operation) <1A <1A <1A <1A <1A wire -). Voltage 140 ~ 275VAC Frequency 45 ~ 65Hz Turn on the device with the ON / OFF button (press and hold the button for 5s until you Input In AC supply mode AVR stabilizer can increase or decrease AC input voltage to a correct level. If AC hear a beep) and connect the plug to the AC socket. AVR stabilizer input voltage is outside of the range 203V AC 1% - 239V AC 1%, then output voltage will be ~213V AC 1% and will increase accordingly to the value of input voltage. Set the AC charger switch to the position to start charging the battery and select AC Voltage 230V AC 1% in battery mode 230V AC 8% in AC supply mode with AVR PRIORITY. Frequency 50Hz 0.5Hz Connect all devices that you want to use with the power supply, make sure they are turned Output Voltage Pure sinusoidal wave off and after connecting, turn them on one by one. waveform Distortions <3% In models with build-in work priority switch, after connecting the regulator, select the Priority selection button (mains / YES (Only in E SOLAR PRIORITY option. NO YES YES NO battery) PLUS version) TURNING OFF UPS YES (E PLUS: Charging current selection (5/10A) YES YES NO NO 2/5/10A) One by one turn off devices connected to the converter. Overload, temperature, over- and under-voltage, against battery discharging, short circuit, against Protection overcharging Set the AC charger switch to the 0 position to stop the battery charging process. Switching time (mains/battery) 4ms Press and hold ON / OFF button for 3 seconds to disconnect converter output. Battery voltage 12V DC 24V DC Disconnect power supply cable. Maximum charging current A 10 Dimensions width x depth x height Disconnect the battery from the converter. 230 x 145 x 180 350 x 150 x 190 355 x 220 x 250 355 x 220 x 250 mm Weight 5.1kg 6.5kg 7.1kg 10.7kg 16.4kg CAUTIONS Be careful while connecting the battery, voltage generated with reverted polarity can damage the converter. X-ON Electronics Largest Supplier of Electrical and Electronic Components Click to view similar products for Power Inverters category: Click to view products by Volt manufacturer: Other Similar products are found below : PV-400FC PV550 ISI-501-224B 3SIP500012 IPS-800 12V/230V IPS-900 24V/230V SINUS600 24V PE-35 PE-40 PS-250 TS-1500-224B ISI-500-148A TS-1000-224B TS400-124F TS200-112F TS400-224B TS-3000-112F TS200-224B TN-3000-124F TN-1500-248B IRC3(10ft. Cable) TS200-148F IPS-1000S 12V/230V ECO MODE IPS-1200S 24V/230V ECO MODE IPS-4000S 12V/230V ECO MODE IPS-5000S 24V/230V ECO MODE IPS-800U 12V/230V 3IPS030012 3IPS030024 3IPS40012 3IPS40024 3IPS050012 SINUS-10000PRO 12V SINUS-600PRO 12V SINUS-850PRO 12V SINUSPRO-1000E 3SP091512E 3IPS050024 3IPS100024 3IPS200024 3IPS500012 3IPS500024 3IPS651012 3IPS651024 3IPS912246 3IPS912249 RED-16 24/12V 16A RED-6 24/12V 6A DC-120 12/24V 4A DC 200 24/12V 10A