home vj series apo series aria series polysafe series multibox series multiboxg series vm series vms series series 55 flex-o-box Table of Contents Vynckier Enclosure Systems 271 McCarty St., Houston, Texas 77029 Phone: (713) 374-7850 Toll Free: (888) 837-1114 Fax: (800) 444-1261 www.Vynckier.com EENNCCLLOSOSUURRE E SYSYSSTTEEMMS S IINNC.C. Technical Information 4 VJ Series Enclosures 10 Opaque Cover Enclosures (VJ) 11 Raised Cover Enclosures (RVJ) 12 Clearview Cover Enclosures (CVJ) 13 Bonded Window Cover Enclosures (VJB) 14 Raised Cover with Bonded Window Enclosures (RVJB) 15 Gasketed Window Enclosures (VJG) 16 Push-button Unit Enclosures 17 APO Series Enclosures 18 Opaque Cover Enclosures 19 Transparent Cover Enclosures 25 Inspection Window Enclosures (DT Cover) 31 Inspection Window Kits 37 ARIA Series Enclosures 38 Opaque Cover Enclosures 39 Bonded Window Cover Enclosures 40 Gasketed Window Cover Enclosures 41 Polysafe Series Enclosures 42 Opaque Cover Enclosures 43 Bonded Window Cover Enclosures 46 Gasketed Window Cover Enclosures 49 Multibox Series Enclosures 52 Opaque Cover Enclosures 53 Transparent Cover Enclosures 57 MultiboxG Series Enclosures 61 Opaque Cover Enclosures 62 Transparent Cover Enclosures 64 VM Series Enclosures 66 Opaque Cover Enclosures 67 Transparent Cover Enclosures 69 Push-button Unit Enclosures 71 VMS Series Enclosures 72 Series 55 Series Enclosures 73 Flex-O-Box Series Enclosures 73 Vynckier Enclosure Systems Pedestal Series Enclosures 74 Enclosure Accessories 76 small Catalog Cross Reference Guide 91 2 3 2013home vj series apo series aria series polysafe series multibox series multiboxg series vm series vms series series 55 flex-o-box Vynckier Enclosure Systems 271 McCarty St., Houston, Texas 77029 34-11 56th Street, Woodside, NY 11377 Phone: (713) 374-7850 Toll Free: (888) 837-1114 Call: 800-221-0487 Fax: 718-672-6370 Fax: (800) 444-1261 www.Vynckier.com www.switchesunlimited.com EENNCCLLOSOSUURRE E SYSYSSTTEEMMS S IINNC.C. Environmental ratings for enclosures based on ingress protection Environmental ratings for enclosures based on impact resistance (IK) code designations 3 NEMA: Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental contact with the enclosed IK Number Impact energy (joules) Equivalent impact equipment to provide a degree of protection against falling dirt, rain, sleet, snow, and windblown dust and that will be undamaged by the external formation 00 Non-protected N/A of ice on the enclosure. UL: Outdoor use primarily to provide a degree of protection against rain, sleet, wind blown dust and damage from external ice formation. 01 0.15 Drop of .44 lbs object from 7.5 cm height CSA: Indoor or outdoor use provides a degree of protection against rain, snow and windblown dust undamaged by the external formation of ice on the enclosure. 02 0.2 Drop of .44 lbs object from 10 cm height IP54: Protected against dust - Limited to ingress. Protected against water sprayed from all directions - Limited to ingress permitted. 03 0.35 Drop of .44 lbs object from 17.5 cm height 04 0.5 Drop of .44 lbs object from 25 cm height 3R NEMA: Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment to provide a degree of protection against falling dirt, rain, sleet, and snow and that will be undamaged by the external formation of ice on the 05 0.7 Drop of .44 lbs object from 35 cm height enclosure. UL: Outdoor use primarily to provide a degree of protection against rain, sleet, and damage from external ice formation. 06 1 Drop of 1.1 lbs object from 20 cm height CSA: Indoor or outdoor use provides a degree of protection against rain and snow undamaged by the external formation of ice on the enclosure. IP14: Protected against vertically falling water drops. Protected against water sprayed from all directions - Limited to ingress permitted. 07 07 Drop of 1.1 lbs object from 40 cm height 08 5 Drop of 3.75 lbs object from 29.5 cm height 09 10 Drop of 11 lbs object from 20 cm height 3S NEMA: Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment to provide a degree of protection against falling dirt, rain, sleet, snow, and windblown dust and in which the external mechanisms remain 10 20 Drop of 11 lbs object from 40 cm height operable when ice laden. UL: Outdoor use primarily to provide a degree of protection against rain, sleet, windblown dust and to provide for operation of external mechanisms when ice laden. IP54: Protected against dust - Limited to ingress. Protected against water sprayed from all directions - Limited to ingress permitted. 4 NEMA: Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment to provide a degree of protection against falling dirt, rain, sleet, snow, windblown dust, splashing water, and hose-directed water and that will be undamaged by the external formation of ice on the enclosure. Flame testing data: Unsaturated polyester (UP), glass reinforced, furnished as sheets UL: Indoor or outdoor use primarily to provide a degree of protection against windblown dust and rain, splashing water, hose-directed water and damage from external ice formation. Color Min Thickness (mm) Flame Class HWI HAI RTI Elec RTI Imp RTI Str CSA: Indoor or outdoor use provides a degree of protection against rain, snow, windblown dust, splashing and hose-directed water undamaged by the external formation of ice on the enclosure. All 1.5 HB 0 0 130 130 130 IP66: Protected against dust - Limited to ingress. Protected against strong jets of water from all directions - Limited to ingress permitted. Comparative tracking index (CTI): 0 Dimensional stability (%): - 4X NEMA: Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental contact with the enclosed High-voltage arc tracking rate (HVTR): 0 High-voltage, low current arc resistance (D495): - equipment to provide a degree of protection against falling dirt, rain, sleet, snow, windblown dust, splashing water, hose-directed water, and corrosion and that will be undamaged by the external formation of ice on the enclosure. x Dielectric strength (kV/mm): - Volume resistivity (10 ohm-cm): - UL: Indoor or outdoor use primarily to provide a degree of protection against corrosion, windblown dust and rain, splashing water, hose-directed water, and damage from external ice formation. (f1): Suitable for outdoor use with respect to exposure to ultraviolet light, water exposure and immersion in accordance with UL 746C CSA: Indoor or outdoor use provides a degree of protection against rain, snow, windblown dust, splashing and hose-directed water undamaged by the external formation of ice on the enclosure resists corrosion. ANSI/UL 94 small-scale test data does not pertain to building materials, furnishings and related contents. ANSI/UL 94 small-scale test data is intended solely for IP66: Protected against dust - Limited to ingress. Protected against strong jets of water from all directions - Limited to ingress permitted. determining the flammability of plastic materials used in the components and parts of end-product devices and appliances, where the acceptability of the combustion is determined by UL. 5 NEMA: Enclosures constructed for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment to provide a degree of protection against falling dirt against settling airborne dust, lint, fibers, and flyings and to provide a degree of protection against dripping and light splashing of non-corrosive liquids. UL: Indoor use primarily to provide a degree of protection against settling airborne dust, falling dirt, and dripping noncorrosive liquids. IP52: Protected against dust - Limited to ingress. Protected against direct sprays of water up to 15 from the vertical. 12 NEMA: Enclosures constructed (without knockouts) for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment to provide a degree of protection against falling dirt against circulating dust, lint, fibers, and flyings against dripping and light splashing of non- Chemical resistance ratings against submersion corrosive liquids and against light splashing and consequent seepage of oil and non-corrosive coolants. UL: Indoor use primarily to provide a degree of protection against circulating dust, falling dirt, and dripping noncorrosive liquids. CSA: Indoor use provides a degree of protection against circulating dust, lint, fibers and flyings dripping and light splashing of non-corrosive liquids not 3: Excellent 2: Limited 1: Insufficient FRP: Fiberglass Reinforced Polyester PC: Polycarbonate PS: Polystyrene ABS: ABS Plastic provided with knockouts. IP52: Protected against dust - Limited to ingress. Protected against direct sprays of water up to 15 from the vertical. Chemical Class FRP PC PS ABS Chemical Class FRP PC PS ABS Chemical Class FRP PC PS ABS Water 3 3 3 3 Chlorides 3 3 3 3 Hydrocarbons aromatic 1 1 1 1 12K NEMA: Enclosures constructed (with knockouts) for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment to provide a degree of protection against falling dirt against circulating dust, lint, fibers, and flyings against dripping and light splashing of non- Seawater 3 3 3 3 Alcohols 3 2 2 2 Xylene 2 1 1 1 corrosive liquids and against light splashing and consequent seepage of oil and non-corrosive coolants. UL: Indoor use primarily to provide a degree of protection against circulating dust, falling dirt, and dripping noncorrosive liquids. Acid, diluted 3 3 3 3 Ketones 2 1 2 2 Hydrobarbons halogenated 2 1 1 1 CSA: Indoor use provides a degree of protection against circulating dust, lint, fibers and flyings dripping and light splashing of noncorrosive liquids not provided with knockouts. Acid, conc. 1 2 2 2 Acetone 2 1 1 1 Chlorobenzene 1 1 1 1 IP52: Protected against dust - Limited to ingress. Protected against direct sprays of water up to 15 from the vertical. Acid, oxidized 1 1 2 2 Esters 2 1 1 1 Mineral oils 3 1 1 1 13 NEMA: Enclosures constructed for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment to Alkalis, diluted 2 2 3 3 N-butylacetate 2 1 1 1 Oils and fats 3 1 2 2 provide a degree of protection against falling dirt against circulating dust, lint, fibers, and flyings and against the spraying, splashing, and seepage of water, Alkalis, conc. 1 1 3 3 Ethers 2 1 1 1 Propylene glycol 2 3 3 3 oil, and non-corrosive coolants. UL: Indoor use primarily to provide a degree of protection against dust, spraying of water, oil, and noncorrosive coolant. Ammoniac 1 1 3 3 Hydrocarbons aliphatic 3 3 1 1 Nitrobenzene 1 1 1 1 IP54: Protected against dust - Limited to ingress. Protected against water sprayed from all directions - Limited to ingress permitted. Salt, aqueous sol. 3 3 3 3 White spirit 3 3 1 1 Phenol 1 1 1 1 4 5