Relay Socket with Small Switching Relay 1/2 Socket with relay (2 changeover contacts) and status indication Data sheet 14 A1 11 ~ 12 24 21 A2 22 ~ Similar photo Item-No. Pack.-unit Description pcs Socket with relay, AC 115 V, 2 changeover contacts 788-515 1 Relay socket for DIN 35 carrier rails. Technical Data Status indication through pluggable LED module (red). Contact material AgNi 90/10 Input nominal voltage U AC 115 V N Insulated, pluggable jumper system suitable for both coil Input voltage range U 10 % N and load side. Current input at U (20 C) 8 mA N Max. switching voltage AC 250 V CAGE CLAMP S connection. Max. making current (resistive) Solid wires, fine-stranded wires with crimped ferrules or at 10 % continuous duty 4 s (AC) 15 A ultrasonically bonded wire ends can be inserted directly. Max. continuous current 2 x 8 A Max. switching power Quick exchange of the relay and the status indication (resistive) 2 x AC 2000 VA during maintenance, without having to detach the wiring. (resistive) DC see load limiting value graph Max. number of switching -1 -1 Safe electrical isolation in accordance with DIN VDE 0140 operations with/without load 6 min / 1200 min Part 1. Operating power 0.75 VA Pull-in/dropout/bounce time 7 ms / 2 ms / 3 ms typ. DC-Load limiting value graph Operation at normal rating 100 % continuous duty Dielectric strength 300 2 poles resistive load contact/coil 5 kV 200 open contact 1 kV 2 contacts in series Nominal voltage acc. to VDE 0110 Part1 / 4.97 100 IEC 60664-1 250 V / 4 kV / 3 6 Mechanical life 5 x 10 switching operations 50 1 contact Degree of protection IP 20 40 Relay type RT 2 30 Ambient operating temperature -25 C ... +50 C 20 Storage temperature -40 C ... +70 C Dimensions (WxHxD) (15x53*x86) mm / (0.59x2.09x3.39) in 10 * from upper edge of DIN 35 rail 0,1 0,2 0,5 1 2 5 10 20 Current A Note: Inductive loads have to be attenuated by an appropriate protective circuit in order to protect relay coils and contacts WAGO Kontakttechnik GmbH & Co. KG Postfach 2880 D-32385 Minden Tel.: 05 71 / 8 87-0 E-Mail: info wago.com Hansastr. 27 D-32423 Minden Fax.: 05 71 / 8 87-169 Web: Relay Socket with Small Switching Relay 2/2 Socket with relay (2 changeover contacts) and status indication Data sheet Wire connection CAGE CLAMP S Commoning possibilities on the contact side: 0,34-2,5 mm / AWG 22-12 -relay internal contacts 11/21 Stripped length 9-10 mm / 0.37 in -relay spanning contacts 11/11 Standards / prescriptions DIN VDE 0140 Part1, DIN EN 61140 DIN VDE 0160, EN 50178 Class of protection II Approvals UL C US UL508 / CSA22.2 E175199 Only use replacement relay 788-176 for UL applications (see accessories) Accessories: Comb type jumper bar 18 A, 2-way 788-113 18 A, 3-way 788-114 18 A, 4-way 788-115 18 A, 6-way 788-116 18 A, 8-way 788-117 18 A, 2-way 859-402 Operation indication AC 115 V 788-124 Relay RT2, 2 CO 788-176 WMB Multi marking system (General catalogue W3 Vol.1 Chapt.8) Commoning possibilities on the coil side: -contacts A2/A2 WAGO Kontakttechnik GmbH & Co. KG Postfach 2880 D-32385 Minden Tel.: 05 71 / 8 87-0 E-Mail: info wago.com Hansastr. 27 D-32423 Minden Fax.: 05 71 / 8 87-169 Web: