Data sheet Weidmller Interface GmbH & Co. KG WDU 35 Klingenbergstrae 26 D-32758 Detmold Germany www.weidmueller.com Product image Power feed-in Our wide range of W-Series terminal blocks with our WPD main line branch terminals, which are optimised to guarantee both convenience and space gains, ensures a secure and convenient connection at the power feed-in. General ordering data Version Feed-through terminal, Screw connection, 35 mm, 1000 V, 125 A, dark beige Order No. 1020500000 Type WDU 35 GTIN (EAN) 4008190077013 Qty. 40 pc(s). Creation date January 8, 2022 11:07:17 AM CET Catalogue status 17.12.2021 / We reserve the right to make technical changes. 1Data sheet Weidmller Interface GmbH & Co. KG WDU 35 Klingenbergstrae 26 D-32758 Detmold Germany www.weidmueller.com Technical data Dimensions and weights Depth 62.5 mm Depth (inches) 2.461 inch Depth including DIN rail 63 mm Height 60 mm Height (inches) 2.362 inch Width 16 mm Width (inches) 0.63 inch Weight 54 g Net weight 51.38 g Temperatures Storage temperature Operating temperature range For operating temperature range see EC Design Test Certificate / IEC Ex- -25 C...55 C Certificate of Conformity Continuous operating temp., min. -60 C Continuous operating temp., max. 130 C Material data Material Wemid Colour dark beige UL 94 flammability rating V-0 Rating data IECEx/ATEX Certificate No. (ATEX) DEMKO14ATEX1338U Certificate No. (IECEX) IECEXULD14.0005U Max. voltage (ATEX) 690 V Current (ATEX) 115 A Wire cross section max. (ATEX) 35 mm Max. voltage (IECEX) 690 V Current (IECEX) 115 A Wire cross section max. (IECEX) 35 mm Operating temperature range For operating temperature Marking EN 60079-7 range see EC Design Test Certificate / IEC Ex- Certificate of Conformity Ex eb II C Gb Ex 2014/34/EU label II 2 G D System specifications Version Screw connection, End cover plate required for screwable cross- connection, One end without connector Yes Number of potentials 1 Number of levels 1 Number of clamping points per level 2 Number of potentials per tier 1 Levels cross-connected internally No PE connection No Rail TS 35 N-function No PE function No PEN function Yes 2 clampable conductors (H05V/H07V) with equal cross-section (rated connection) Cross-section for connected wire, Cross-section for connected wire, stranded, two clampable wires, max. 16 mm stranded, two clampable wires, min. 16 mm Wire connection cross section, finely Wire connection cross section, finely stranded with wire-end ferrules DIN stranded with wire-end ferrules DIN 46228/1, 2 clampable wires, max. 16 mm 46228/1, 2 clampable wires, min. 2.5 mm Wire connection cross section, finely Wire cross-section, finely stranded, two stranded, two clampable wires, min. 2.5 mm clampable wires, max. 16 mm Creation date January 8, 2022 11:07:17 AM CET Catalogue status 17.12.2021 / We reserve the right to make technical changes. 2