Data sheet Weidmller Interface GmbH & Co. KG VSSC6TRCLFG24VAC/DC EX Klingenbergstrae 26 D-32758 Detmold Germany www.weidmueller.com Overvoltage coupling along the conductor path may General ordering data disturb or destroy sensitive signal inputs. It is important to provide protection in the immediate vicinity of I&C Version Surge protection for instrumentation and control, Surge protection for measurement and control, devices. Weidmller s broad product range for the I&C U (L/N-PE) 1870 V P sector offers products in a 2-piece, pluggable design and Order No. 1066490000 modular terminals for tension clamp or screw connection. Type VSSC6TRCLFG24VAC/DC EX These products are suitable for both binary and analogue GTIN (EAN) 4032248820122 signals. Weidmller also offers other designs with Qty. 1 pc(s). integrated components such as gas discharge tubes or varistors. VARITECTOR stands for flexible and variable surge protection by Weidmller, tested according to product standard IEC61643-21. The VARITECTOR series can be used in applications according to IEC 61643-22 / VDE 0845-3 for classes C1, C2, C3 and D1. The VARITECTOR SPC, SSC and MCZ OVP product families optimally combine electrical and mechanical properties. Size and easy handling play an important role. This surge protection is suited for confined spaces in industrical and process automation as well as in building automation applications. Creation date January 20, 2022 4:39:25 AM CET Catalogue status 14.01.2022 / We reserve the right to make technical changes. 1Data sheet Weidmller Interface GmbH & Co. KG VSSC6TRCLFG24VAC/DC EX Klingenbergstrae 26 D-32758 Detmold Germany www.weidmueller.com Technical data Dimensions and weights Depth 81 mm Depth (inches) 3.189 inch Height 88.5 mm Height (inches) 3.484 inch Width 12.4 mm Width (inches) 0.488 inch Net weight 60.6 g Temperatures Storage temperature -40 C...80 C Operating temperature -40 C...70 C Humidity 5...96 % Probability of failure SIL PAPER SIL Paper SIL in compliance with IEC 61508 3 MTTF 3,936 Jahre SFF 93.28 % -9 ges 29 PFH in 1*10 per hour 1.95 Environmental Product Compliance REACH SVHC Lead 7439-92-1 Protection Ex - Data ATEX - dust labelling II 1 D Ex ia IIIC T135 C ATEX - gas labelling T85 C Da II 1 G Ex ia IIC T4 T6 Ga IECEx - dust labelling II 1 D Ex ia IIIC T135 C IECEx - gas labelling T85 C Da II 1 G Ex ia IIC T4 T6 Ga Input power, max. P Input voltage, max. U I 0.75 W i 42 V Internal capacity, max. C Internal inductance, max. L I 2 nF I 0 H Temperature class T4/135C (-40C ... Temperature class T5/100C (-40 C ... +120 C) li 300 mA +85 C) li 300 mA Temperature class T6/85 C (-40 C ... +70 C) li 300 mA CSA protection data Gas group C IIB Gas group D IIA Gas groups A, B Input current, max. I IIC I 300 mA Input voltage, max. U Internal capacity, max. C i 42 V I 1 nF Internal inductance, max. L I 0 H General data Colour Light Blue Design Terminal Isolating function Yes Optical function display No Protection degree IP20 Rail TS 35 Segment Testing option Functional screw with Measurement - Monitoring test plug receptacle, - Setting connections 1, 2, 4, 5 UL 94 flammability rating Version Surge protection for V-0 measurement and control Insulation coordination acc. to EN 50178 Pollution severity 2 Surge voltage category III Creation date January 20, 2022 4:39:25 AM CET Catalogue status 14.01.2022 / We reserve the right to make technical changes. 2