Data sheet Weidmller Interface GmbH & Co. KG TOZ 24VDC 230VAC1A Klingenbergstrae 26 D-32758 Detmold Germany www.weidmueller.com Product image Similar to illustration 1 NO contact (Triac (zero-cross switch)) 6.4 mm wide 1 A AC output current Unique multi-voltage input from 24 to 230 V UC Input voltages from 12 V DC to 230 V UC with coloured marking: AC: red, DC: blue, UC: white General ordering data Version TERMSERIES, Solid-state relay, Rated control voltage: 24 V DC 20 % , Rated switching voltage: 24...240 V AC, Continuous current: 1 A, Tension- clamp connection Order No. 1127530000 Type TOZ 24VDC 230VAC1A GTIN (EAN) 4032248909346 Qty. 10 pc(s). Creation date January 21, 2022 1:18:09 AM CET Catalogue status 14.01.2022 / We reserve the right to make technical changes. 1Data sheet Weidmller Interface GmbH & Co. KG TOZ 24VDC 230VAC1A Klingenbergstrae 26 D-32758 Detmold Germany www.weidmueller.com Technical data Dimensions and weights Depth 87.8 mm Depth (inches) 3.457 inch Height 90.5 mm Height (inches) 3.563 inch Width 6.4 mm Width (inches) 0.252 inch Net weight 29.5 g Temperatures Storage temperature -40 C...70 C Operating temperature -20 C...60 C Humidity 5-95% relative humidity, T = 40C, without u condensation Probability of failure MTTF 1,120 Years Environmental Product Compliance REACH SVHC Lead 7439-92-1 Rated data UL Ambient temperature (operational), max. Output current derating (ohmic) 1 A 25 C, 0.3 A 60 60 C C Connection cross-section AWG, min. AWG 26 Connection cross-section AWG, max. AWG 14 Type of conductor rigid copper conductor, Pollution severity level flexible copper conductor 2 Control side Rated control voltage 24 V DC 20 % Nominal control current 11.5 mA DC (10 %) Power rating 280 mW Pull-in/drop-out voltage, typ. 12 V / 6.5 V DC Status indicator Protective circuit Free-wheeling diode, Green LED Reverse polarity protection Coil voltage of the replacement relay Coil voltage of the replacement relay deviating from the rated control voltage No 24 V DC Load side Rated switching voltage 24...240 V AC Continuous current 1 A Voltage drop at max. load 1.6 V Min. switching current 20 mA Inrush current 15 A / 10 ms Leakage current < 1.5 mA Switch-on delay 12 ms Switch-off delay 12 ms Output voltage frequency range max. switching frequency (DC control 50 / 60 Hz voltage) 3 Hz Protective circuit, load side RC element Short-circuit-proof No Contact type 1 NO contact (Triac (zero- cross switch)) General data Rail TS 35 Test button available No Colour black Creation date January 21, 2022 1:18:09 AM CET Catalogue status 14.01.2022 / We reserve the right to make technical changes. 2