Data sheet Weidmller Interface GmbH & Co. KG ACT20P Klingenbergstrae 16 ACT20P-AI-AO-DC-S D-32758 Detmold Germany Fon: +49 5231 1429-0 Fax: +49 5231 14292083 www.weidmueller.com ACT20P: The flexible solution Precise and highly functional signal converters Simple configuration via display (Pro DCDC II), FDT/ DTM software or DIP switch Release levers simplify handling More space in the control cabinet, from 12.5 mm wide for two channels General ordering data Type ACT20P-AI-AO-DC-S Order No. 1477420000 Version ACT20P, Signal converter/insulator, Input, DC U/I signals, Screw connection GTIN (EAN) 4050118284959 Qty. 1 pc(s). Creation date September 1, 2017 4:55:07 PM CEST Catalogue status 25.08.2017 / We reserve the right to make technical changes. 1Data sheet Weidmller Interface GmbH & Co. KG ACT20P Klingenbergstrae 16 ACT20P-AI-AO-DC-S D-32758 Detmold Germany Fon: +49 5231 1429-0 Fax: +49 5231 14292083 www.weidmueller.com Technical data Dimensions and weights Width 12.5 mm Width (inches) 0.492 inch Height 117.2 mm Height (inches) 4.614 inch Depth 113.7 mm Depth (inches) 4.476 inch Weight 80 g Net weight 80 g Temperatures Humidity 10...90 % (no Operating temperature condensation) -20 C...60 C Storage temperature -25 C...70 C Input Number of inputs 1 Sensor supply 24 V DC Input voltage configurable, 011 V (min. Input resistance, voltage measurement range 2V) 1 M Input current configurable, 022 mA Input resistance, current (min. measurement range 4 mA) 100 Resolution 3.5 A / 1.76 mV per bit Output Number of outputs Output voltage, note adjustable, 0...11 V, min. 1 output range 2V Output current adjustable, 0...22 mA, min. load impedance voltage output range 4 mA 500 k load impedance current 1k Offset voltage 20 mV General data Configuration DIP switch, Keys and LED Galvanic isolation 3-way isolator, between display input output supply Linearity < 0.1 % of signal range, Long-term drift Typ. 0.05 % of signal range 0.1 % / 10.000 h Mounting rail TS 35 Power consumption, typ. 3 W Step response time 350 ms Supply voltage 12...60 V DC Temperature coefficient < 0.05 % / C Insulation coordination EMC standards Galvanic isolation 3-way isolator, between IEC 61326-1 input output supply Impulse withstand voltage 4 kV (1.2/50 s) Insulation voltage 2 kV inputs / outputs Pollution severity Standards IEC 61326-1:2012, UL 61010-1:2012, 3rd 2 Edition Surge voltage category III Creation date September 1, 2017 4:55:07 PM CEST Catalogue status 25.08.2017 / We reserve the right to make technical changes. 2