Data sheet Weidmller Interface GmbH & Co. KG ACT20P Klingenbergstrae 16 ACT20P-CML-10-AO-RC-S D-32758 Detmold Germany Fon: +49 5231 1429-0 Fax: +49 5231 14292083 www.weidmueller.com ACT20P: The flexible solution Precise and highly functional signal converters Simple configuration via display (Pro DCDC II), FDT/ DTM software or DIP switch Release levers simplify handling More space in the control cabinet, from 12.5 mm wide for two channels General ordering data Type ACT20P-CML-10-AO-RC-S Order No. 2044850000 Version Current-measuring transducer, Limit value monitoring, Signal converter/isolator, Current monitoring, Analogue output, Screw connection, Input measurement range: configurable, 0 1/5/10 A AC (RMS) or DC GTIN (EAN) 4050118409680 Qty. 1 pc(s). Creation date October 26, 2017 11:07:19 AM CEST Catalogue status 25.10.2017 / We reserve the right to make technical changes. 1Data sheet Weidmller Interface GmbH & Co. KG ACT20P Klingenbergstrae 16 ACT20P-CML-10-AO-RC-S D-32758 Detmold Germany Fon: +49 5231 1429-0 Fax: +49 5231 14292083 www.weidmueller.com Technical data Dimensions and weights Width 17.5 mm Width (inches) 0.689 inch Height 119.2 mm Height (inches) 4.693 inch Depth 113.6 mm Depth (inches) 4.472 inch Net weight 141 g Temperatures Humidity 5...95 %, no condensation Operating temperature Ambient temperature -25 C...+70 C Storage temperature -40 C...85 C Probability of failure MTTF 130 Years Input Number of inputs Input signal Power cable can be 1 connected to the terminals Input measurement range Input frequency AC: 15400 Hz (true root configurable, 01/5/10 A mean square), AC: 50 Hz AC (RMS) or DC (arithmetic average) General data Accuracy 0.3 % 1 A 5 A, Configuration DIP switch and 0.6 % 10 A potentiometer Galvanic isolation 4-way isolator , between Mounting rail input output supply relay TS 35 Power consumption, max. Step response time 300 ms (RMS), 60 ms 2.2 W (AA) Supply voltage Temperature coefficient 100 ppmK -25 +55 C, 200 ppm/K 24 V DC 30 % +55+70 C Insulation coordination EMC standards Galvanic isolation 4-way isolator , between IEC 61326-1, IEC input output supply 61010-2-201 relay Impulse withstand voltage 6 kV (1.2/50 s) Pollution severity 2 Rated voltage Standards IEC 61010-1:2010, 3rd Edition, IEC 61010-2-201:2013, 1st 300 V AC rms Edition Surge voltage category III Test voltage 4 kV Output (analogue) Load resistance current 600 Load resistance voltage 10 k Output current Output voltage adjustable, 0...10 V, 210 adjustable, 0...20 mA, V, 0...5 V, 1...5 V, -5+5 V, 4...20 mA, -20+20 mA -10...+10 V Type (analogue output) Voltage and current output (configurable) Creation date October 26, 2017 11:07:19 AM CEST Catalogue status 25.10.2017 / We reserve the right to make technical changes. 2