Data sheet Weidmller Interface GmbH & Co. KG maxGUARD Klingenbergstrae 16 AMG ELM-2F D-32758 Detmold Germany Fon: +49 5231 1429-0 Fax: +49 5231 14292083 www.weidmueller.com Efficient machine and facility operation calls for fail-safe and maintenance-friendly control voltage distribution that can be installed in a time and space-saving manner. With the new maxGUARD system, the terminal blocks (previously installed separately) for distributing potential to the outputs of the electronic load monitors become an integral part of a 24 V DC control voltage distribution system. The innovative combination of load monitoring and potential distribution saves time during installation, increases safety against failure and reduces the amount of space required on the terminal rail by 50%. General ordering data Type AMG ELM-2F Order No. 2080480000 Version Electronic load monitoring, 2.00 A, 24 V DC GTIN (EAN) 4050118419504 Qty. 1 pc(s). Creation date August 15, 2017 11:55:38 AM CEST Catalogue status 14.08.2017 / We reserve the right to make technical changes. 1Data sheet Weidmller Interface GmbH & Co. KG maxGUARD Klingenbergstrae 16 AMG ELM-2F D-32758 Detmold Germany Fon: +49 5231 1429-0 Fax: +49 5231 14292083 www.weidmueller.com Technical data Dimensions and weights Width 6.1 mm Width (inches) 0.24 inch Height 125 mm Height (inches) 4.921 inch Depth 96.5 mm Depth (inches) 3.799 inch Net weight 40 g Temperatures Operating temperature -25 C...55 C Storage temperature -40 C...85 C Probability of failure MTTF 350 Years Input Current consumption (full load) I +30 mA Current consumption (idle) OUT 25 mA DC input voltage range 1830 V DC Input fuse (internal) Yes Rated input voltage 24 V DC Surge protection Suppressor diode max. admissible residual ripple at the input 100 mVpp output Capacitive load 10,000 F Connection system PUSH IN Rated current 2 A Surge protection Suppressor diode Switch-on delay 1 s Triggering characteristic see characteristic curve adjustable rated current No General data Function key Activation time < 3s, Reset, Operating temperature ON -25 C...55 C Protection degree IP20 Relay to activate the output No Surge voltage category III Insulation coordination Surge voltage category III Connection data (output) Conductor cross-section, AWG/kcmil , Conductor cross-section, AWG/kcmil , max. 12 min. 26 Conductor cross-section, flexible , max. 2.5 mm Conductor cross-section, flexible , min. 0.14 mm Conductor cross-section, rigid , max. 2.5 mm Conductor cross-section, rigid , min. 0.14 mm Connection system PUSH IN Number of terminals 2 (+ / -) Screwdriver blade 0.6 x 3.5 Signalling LED green LED red Load monitoring has disconnected, Load monitoring has triggered (flashing), Internal error Operation (failure-free) (rapid flashing) Creation date August 15, 2017 11:55:38 AM CEST Catalogue status 14.08.2017 / We reserve the right to make technical changes. 2