Electronic Pressure Measurement Pressure transmitter for general industrial applications Model A-10 WIKA Data Sheet PE 81.60 Applications Mechanical engineering Machine tools Control and feedback control systems Hydraulics / Pneumatics Pumps/ Compressors Special Features Pressure ranges: from 0 1 bar up to 0 600 bar Non-linearity: 0.25 % or 0.5 % Signal output: 4 ... 20 mA, 0 ... 10 V, 0 ... 5 V and other Electrical connection: DIN 175301-803 A and C, M12x1, Flying leads 2m Pressure connection: G1/4 DIN 3852-E, 1/4 NPT and Pressure transmitter A-10 others Description Simple - reliable competitive The WIKA A-10 can be used for a multitude of functions across many different applications. Exceptionally simple installation, set-up and operation with an excellent price/performance ratio set this highly-reliable product apart. WIKA Data Sheet PE 81.60 07/2009 Page 1 of 4 Data Sheets for related models Pressure transmitter for general applications Model S-10 see Data Sheet PE 81.01Specifications Model A-10 Pressure ranges bar 1 1.6 2,5 4 6 10 16 25 Over pressure safety bar 2 3.2 5 8 12 20 32 50 Burst pressure bar 5 10 10 17 34 34 100 100 Pressure ranges bar 40 60 100 160 250 400 600 Over pressure safety bar 80 120 200 320 500 800 1200 Burst pressure bar 400 550 800 1000 1200 1700 2400 2 MPa and kg/cm are available Absolute pressure: 0 ... 1 bar up to 0 ... 25 bar compound ranges: -1 ... 0 bar up to -1 ... 24 bar Pressure ranges psi 15 25 30 50 100 160 200 300 Over pressure safety psi 30 60 60 100 200 290 400 600 Burst pressure psi 75 150 150 250 500 500 1500 1500 Pressure ranges psi 500 1000 1500 2000 3000 5000 10000 Over pressure safety psi 1000 1740 2900 4000 6000 10000 17400 Burst pressure psi 2500 7975 11600 14500 17400 24650 34800 Absolute pressure: 0 ... 15 psi up to 0 ... 300 psi compound ranges: -30 inHg ... 0 psi up to -30 inHg ... 300 psi Vacuum resistance As of 0 ... 10 bar Fatigue life 10 Mio. max. load cycles Materials Wetted parts Pressure Connection 316 L Pressure sensor 316 L (as of 0 ... 10 bar rel 13-8 PH) Internal transmission fluid Silicone oil (only with pressure ranges < 0 ... 10 bar and 0 ... 25 bar abs) Case 316 L 1) Power supply UB U+ in VDC 8 ... 30 8 ... 36 maximum ohmic load R 14 ... 30 14 ... 36 with signal output 0 ... 10 V A 5 10 % with signal output 0.5 ... 4.5 V ratiometric 1) not with non-linearity 0.25 % BFSL and 4 ... 20 mA Signal output and R in Ohm 4 ... 20 mA, 2-wire R (U+ 8 V) / 0.02 A A A maximum ohmic load R 0 ... 10 V, 3-wire R > 10 k A A 0 ... 5 V, 3-wire R > 5 k A 1 ... 5 V, 3-wire R > 5 k A 0.5 ... 4.5 V, 3-wire R > 4.5 k A 0.5 ... 4.5 V, ratiometric R > 4.5 k other signal outputs on request A Setting time ms < 4 Current consumption mA Signal current (max. 25) for current output Max. 8 for voltage output signal ) 2 Insulation voltage VDC 500 2) For power supply, use a circuit with energy limitation (EN/UL/IEC 61010-1, section 9.3) with the following maximum values for the current: bei U+ = 30 V (DC): 5 A. Provide a separate switch for the external power supply. Alternative for North America: The connection may also be made to Class 2 Circuits or Class 2 Power Units according to CEC (Canadian Electrical Code) or NEC (National Electrical Code). Non-linearity % of span 0.25 (BFSL) according to IEC 61298-2 0.5 (BFSL) according to IEC 61298-2 Adjusted in vertical mounting position with lower pressure connection ) 3 Accuracy % of span 0.5 (with non-linearity 0.25 %) 0.6 (with non-linearity 0.25 % and with signal output 0 ... 5 V) 1.0 (with non-linearity 0.5 %) 3) Including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement per IEC 61298-2) Zero offset % of span 0.15 typ., 0.4 max. (with non-linearity 0.25 %) 0.5 typ., 0.8 max. (with non-linearity 0.5 %) Hysteresis % of span 0.16 Non-repeatability % of span 0.1 Long-term drift % of span 0.1 according to IEC 61298-2 Signal noise % of span 0.3 Page 2 of 4 WIKA Data Sheet PE 81.60 07/2009