D WIMA DC-LINK MKP 5 Metallized Polypropylene (PP) - Capacitors in Cylindrical Case for DC-Link Applications. Capacitances from 16 mF to 260 mF. Rated Voltages from 500 VDC to 1300 VDC. Special Features Electrical Data Very high volume/capacitance ratio Capacitance range: 16 mF to 260 mF Dielectric loss factor tan d : 0 -4 Self-healing properties Rated voltages: 500 VDC, 700 VDC, 2 x 10 With cylindrical plastic case for 900 VDC,1100 VDC, 1300 VDC Test voltage: 1.5 U , 2sec r PCB mounting Capacitance tolerances: 20%, 10% Dielectric absorption: Dry construction without electrolyte (5% available subject to special enquiry) 0.05 % or oil Operating temperature range: Reliability: No internal fuse required 40+ C to +85+ C Operational life 100 000 hours Negative capacitance change Insulation resistance at +20+ C: Failure rate < 50 fit (hot spot 70 C) versus temperature 5 000 sec (M x mF) Very low dielectric absorption (mean value: 20 000 sec) According to RoHS 2011/65/EU Measuring voltage: 100 V/1 min. Customer-specific capacitances or voltages on request Mounting Recommendation Packing Typical Applications Excessive mechanical strain, e.g. pressure Transportation-safe packing in DC capacitors with high capacitances or shock onto the capacitor body, is to be cardboard boxes. for applications in power electronics avoided during mounting and usage of the also at non-sinusoidal voltages and capacitors. For further details and graphs please refer currents e.g. in to Technical Information. Wind power systems Inverters Construction Dielectric: Polypropylene (PP) film Capacitor electrodes: Vacuum-deposited Internal construction: The capacitors are non-polarized. The Plastic film centre termination is designed as one Vacuum-deposited pole whereas the four outer terminations electrode Metal contact layer form the other pole. (schoopage) Termination Encapsulation: Solvent-resistant, flame-retardant plastic case with PU-sealing, UL 94 V-0 Terminations: Tinned wire. Marking: Colour: Grey. Marking: Black on silver label. 129 04.16D WIMA DC-LINK MKP 5 Continuation General Data D x L I (1 kHz)* ESR (1 kHz)* R L Approx. weight rms th e C Part number U N R mm A m K/W nH g 85 mF 50 x 57 35 2.0 11.0 < 45 120 DCP5H15850D000 500 VDC 50 x 95 32 3.4 7.5 < 65 190 DCP5H16195D100 195 260 50 x 120 30 5.2 6.0 < 85 220 DCP5H16260D200 59 mF 50 x 57 30 1.9 11.0 < 45 120 DCP5K05590D000 700 VDC 143 50 x 95 32 3.5 7.5 < 65 190 DCP5K06143D100 190 50 x 120 25 4.7 6.0 < 85 220 DCP5K06190D200 53 mF 50 x 57 35 2.3 11.0 < 45 120 DCP5N05530D000 900 VDC 114 50 x 95 32 4.2 7.5 < 65 190 DCP5N06114D100 50 x 120 30 6.0 6.0 < 85 220 DCP5N06158D200 158 50 x 57 20 2.8 11.0 < 45 120 DCP5P05300D000 30 mF 1100 VDC 72 50 x 95 25 4.5 7.5 < 65 190 DCP5P05720D100 100 50 x 120 25 6.1 6.0 < 85 220 DCP5P06100D200 16 mF 50 x 57 20 3.0 11.0 < 45 120 DCP5R25160D000 1300 VDC 40 50 x 95 25 5.7 7.5 < 65 190 DCP5R25400D100 55 50 x 120 25 7.7 6.0 < 85 220 DCP5R25550D200 Contacts can handle: peak currents up to 1.1 kA Customer-specific capacitances or voltages on request surge currents I up to 3.5 kA S * General guide Part number completion: Dims. in mm. Tolerance: 20 % = M 10 % = K 5 % = J Packing: bulk = S Pin length: none = 00 D L 50 57 50 95 50 120 Rights reserved to amend design data without prior notification. 130 04.16