PS
Characteristics
PS
Electrostatic capacitance
Between open Contacts Approx.0.4pF Item 4.41 of IEC 61810-7
Between coil & Contacts Approx.0.9pF Item 4.41 of IEC 61810-7
R
R50044271 Between Contact Poles Approx.0.2pF Item 4.41 of IEC 61810-7
C USE169380
14.2 9.3 5.3
1000M min (at 500VDC) Item 7 of IEC 61810-5
Insulation Resistance
Features
Dielectric Strength
Surface mount Type with L SMT shaped Terminals.
Between open Contacts 1000VAC 1min
Item 6 of IEC 61810-5
Conforms to FCC Part 68 1.5kV Surge and Dielectric 1000VAC.
Between coil & Contacts 1000VAC 1min
Item 6 of IEC 61810-5
Monostable or bistable relays Single and double Coil magnet latching Type available.
Application for Telecommunication Equipment,Office Equipment, Security Alarm Systems, Measuring instruments, Between Contact Poles 1000VAC 1min
Item 6 of IEC 61810-5
Medical Monitoring Equipment,Audio Visual Equipment, Flight Simulator,Sensor Control.
Surge Withstand Voltage
Between open Contacts 1500V FCC68
Between coil & Contacts 1500V FCC68
Ordering Information
Between Contact Poles 2500V FCC68
PS L 12 W
2
Functional:500m/s 11ms;
1 2 3 4
IEC68-2-27 Test Ea
Shock resistance
2
Survival:1000 m/s 6ms
1 Part number PS 3 Coil rated voltage(V) DC:3,4.5,5,6,9,12,24
10~55Hz Double amplitude Functional 3mm
2 Operating function Nil: Single Side Stable 4 Contact material Nil: AgPd W: AgNi
IEC68-2-6 Test Fc
Vibration resistance
L:1 Coil Latching K:2 Coil Latching
Survival:5mm
Terminals strength 5N IEC68-2-21 Test Ua1
Contact Data
Solderability 235 2 3 0.5s IEC68-2-20 Test Ta method 1
Contact Arrangement 2C DPDT(B-M) Bifurcated Crossbar
Temperature Range -40~85 (-40~185 F)
Contact Material AgPd(Stationary Contact: Gold clad ) AgNi(Gold clad
Mass 1.5g
Contact Rating (resistive) 1A,2A/30VDC; 0.5A/125VAC
Max. Switching Power 60W 62.5VA Min. Switching load 0.01mA/10mV Reference Value
Max. Switching Voltage 220VDC 250VAC Max. Switching Current:2A
Safety approvals
Contact Resistance or
50m Item 4.12 of IEC 61810-7
Safety approval UL&CUR
T VU
Voltage drop
55
2 10 (DC AgPd);1 10 (DC AgNi)
Load 1A,2A/30VDC 0.5A/125VAC 1A/30VDC 0.5A/125VAC
Operation Electrical al 5
Item 4.30 of IEC 61810-7
1 10 (AC)
life
8
Mechanical 10 Item 4.31 of IEC 61810-7
Dimensions mm/inch
CAUTION:
Relays previously tested or used above 10mA resistive at 6V maximum DC or peak AC open circuit are not
recommended for subsequent use in low level applications.
Coil Parameter
Coil voltage
Pick up voltage Release voltage
Release
Index Mark
VDC Coil Operate
Dash VDC(max) VDC(min)
Coil resistance /Reset
power Time
numbers 10% (75%of rated (10% of rated Time
Rated Max.
W ms
voltage ) voltage) ms
0.5 7.62
0.02 0.3
A
PS-003 3 7.5 64.3 2.25 0.3 0.14
2.02 2.54
11.5
B
Stand-off
PS-004 4.5 11.25 144.6 3.38 0.45 0.14 0.020
0.08 0.1
0.453
14.2max.
PS-005 5 12.5 178 3.75 0.5 0.14
0.559max.
Approx.2 Approx.1
PS-006 6 15.0 257 4.50 0.6 0.14
Dimensions
PS-009 9 22.5 579 6.75 0.9 0.14
1.5 0.68
1
PS-012 12 30.0 1028 9.00 1.2 0.14
0.059 0. 02 7 0. 03 9
PS-024 24 48.0 2880 18.0 2.4 0.20
Single Side stable 1 Coil latching 2 Coil latching
1 Coil Latching Reset(Max) Reset
1 2 3 4 5 1 2 3 4 5 1 2 3 4 5
PSL-003 3 8.7 90 2.25 -2.25 0.10
PSL-004 4.5 13.0 202.5 3.38 -3.38 0.10
S R
.
PSL-005 5 14.5 250 3.75 -3.75 0.10 S
Approx.2 Approx.2
PSL-006 6 17.4 360 4.50 -4.50 0.10
R
S: Set
PSL-009 9 26.1 810 6.75 -6.75 0.10
R: Reset
PSL-012 12 34.8 1440 9.00 -9.00 0.10
(Bottom View)
PSL-024 24 57.6 3840 18.0 -18.0 0.15
10 9 8 7 6 10 9 8 7 6 10 9 8 7 6
2 Coil Latching Set Coil Reset Coil Reset(Max) Reset 0.6 1.2 2.54
Index mark Index mark Index mark
0.024 0. 1
0.047
(De-energized Position) (Reset Position) (Reset Position)
PSK-003 3 6 45 45 2.25 2.25 0.20
PSK-004 4.5 9 101 101 3.38 3.38 0.20
Wiring diagram
Soldering Pad (for Terminal)
PSK-005 5 10 125 125 3.75 3.75 0.20
(Bottom view)
Approx.2 Approx.2
PSK-006 6 12 180 180 4.50 4.50 0.20
405
PSK-009 9 18 405 6.75 6.75 0.20 Temporary glue Pad
PSK-012 12 24 720 720 9.00 9.00 0.20
(for Stand-off A or B)
PSK-024 24 36 1920 1920 18.0 18.0 0.30
Tolerance 0.1/ 0.004
NOTES 1).Dimensions are in millimeters.
CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2).Inch equivalents are given for general information only.
Mounting (Bottom view)
2.Pickup and release(reset) voltage are for test purposes only and are not to be used as design
criteria.
3.When latching relays are installed in equipment, the latch and reset coil should not be pulsed
simultaneously. Coil should not be pulsed with less than the nominal coil voltage and pulse width
should be a minimum of three times the specified operate time of the relay. If these conditions are not
followed, it is possible for the relay to be in the magnetically neutral position .
9 . 3 m a x .
0 . 3 6 6 m a x .
+0.4
5.3
+0.016
0.209
9 56
0.376
2
0.079
0.25
0.01
+0.4
6.2
0.016
0.244
3
0.118