Dimensions: mm Recommended Land Pattern: mm Absolute Maximum Ratings (Ambient Temperature 25C): Properties Test conditions Value Unit Power Dissipation P 198 mW Diss 4,0 0,76 0,76 I Peak Forward Current duty/ 10 1 kHz 100 mA F Peak 0,8 1,6 I Continuous Forward Current 85 mA F 0,8 Reverse Voltage V 5 V REV ESD Threshold/ Human Body V 2000 V Model ESD HBM 2 1 1 2 Absolute Thermal Resistance R 38 K/W Junction to Solder Point JS 5 Thermal pad T Junction Temperature 130 C J Optical Properties: Scale - 10:1 Chip Technology InGaN 3,0 Emitting Color Warm White Schematic: Lens Type Top LED General Information: Operating Temperature -40 up to +85 C Polarity Mark (Cathode) Storage Conditions (in original < 40 C < 90 % RH packaging) - + Storage Conditions (for single 1 2 -40 up to +85 C 2 parts) 1 Moisture Sensitivity Level (MSL) 3 Scale - 10:1 CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION METHOD ZAn 003.000 2021-07-01 DIN ISO 2768-1m DESCRIPTION WL-SWTP SMT White Top view Wrth Elektronik eiSos GmbH & Co. KG ORDER CODE EMC & Inductive Solutions PLCC Max-Eyth-Str. 1 158302230 74638 Waldenburg Germany SIZE/TYPE BUSINESS UNIT STATUS PAGE Tel. +49 (0) 79 42 945 - 0 www.we-online.com 3022 eiPal Valid 1/10 eiSos we-online.com This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance. 2,0 1,37 0,25 0,8 1,4 2,0Electrical & Optical Properties: Viewing Angle: Value Properties Test conditions Unit min. typ. max. c Chromaticity Coordinate X 60 mA 0.4293 x c Chromaticity Coordinate Y 60 mA 0.396 y Luminous Flux 60 mA 18 20 lm V V Forward Voltage 60 mA 3.2 3.5 V F Correlated Color Temperature CCT 60 mA 3000 K Reverse Current I 5 V 5 A REV 0 - 60 Color Rendering Index CRI 60 mA 80 85 10 100 20 2 Viewing Angle Phi 0 60 mA 120 50% 30 90 40 80 Certification: 45 RoHS Approval Compliant 2011/65/EU&2015/863 70 50 REACh Approval Conform or declared (EC)1907/2006 60 Halogen Free Conform JEDEC JS709B 50 60 Halogen Free Conform IEC 61249-2-21 40 70 30 20 80 10 90 -90 -45 0 10 20 30 40 50 60 70 80 90 100 CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION METHOD ZAn 003.000 2021-07-01 DIN ISO 2768-1m DESCRIPTION WL-SWTP SMT White Top view Wrth Elektronik eiSos GmbH & Co. KG ORDER CODE EMC & Inductive Solutions PLCC Max-Eyth-Str. 1 158302230 74638 Waldenburg Germany SIZE/TYPE BUSINESS UNIT STATUS PAGE Tel. +49 (0) 79 42 945 - 0 www.we-online.com 3022 eiPal Valid 2/10 eiSos we-online.com This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance. Relative Luminous Intensity (%)