Dimensions: mm Electrical Properties: Properties Value Unit Shielding Effectiveness 100 80 dB MHz 1000,0 u2,5 Shielding Effectiveness 1 GHz 86 dB Surface Resistance 1) R 0.08 S 1) Measurement equipment: Loresta AX MCP-T370 detail A A 4,0 u0,5 General Information: Operating Temperature -40 up to +85 C (Scale-1:10) Storage Conditions (in original < 40 C < 75 % RH packaging) Moisture Sensitivity Level (MSL) 1 Flammability: UL94 V-0 (File Number E474708) Test conditions of Electrical Properties: +20 C, 33 % RH if not specified differently Scale - 1:1 Material Metallized Fiber CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION METHOD Polyether Urethane Foam ViMa 005.003 2020-03-06 DIN ISO 2768-1m Rayon Paper with acrylic DESCRIPTION adhesive WE-LT Conductive Shielding Wrth Elektronik eiSos GmbH & Co. KG Reactive Polyurethane Hotmelt ORDER CODE EMC & Inductive Solutions Gasket Adhesive Max-Eyth-Str. 1 3020403 74638 Waldenburg Germany SIZE/TYPE BUSINESS UNIT STATUS PAGE Tel. +49 (0) 79 42 945 - 0 www.we-online.com Square eiSos Valid 1/3 eiSos we-online.com This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance. 3,0 u0,5Typical Shielding Effectiveness: 100 80 60 40 20 0 0.1 1 10 Frequency GHz CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION METHOD ViMa 005.003 2020-03-06 DIN ISO 2768-1m DESCRIPTION WE-LT Conductive Shielding Wrth Elektronik eiSos GmbH & Co. KG ORDER CODE EMC & Inductive Solutions Gasket Max-Eyth-Str. 1 3020403 74638 Waldenburg Germany SIZE/TYPE BUSINESS UNIT STATUS PAGE Tel. +49 (0) 79 42 945 - 0 www.we-online.com Square eiSos Valid 2/3 eiSos we-online.com This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance. Shielding effectiveness dB