O 7,8 Dimensions: mm Recommended Cable Stripping Dimension: mm 9,8 4,3 2 1,5 6.35 HEX 10-56UNS-2A 4.4 FLAT 6.35 HEX Scale - 8:1 Recommended Panel Cutout: mm 6,6 6,35 7 7,8 14,5 Scale - 8:1 Scale - 3,5:1 CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION Article Properties: METHOD JaC 002.000 2021-11-19 DIN ISO 2768-1m Properties Value Unit DESCRIPTION Ferrule Hex Crimp Size 0.128 in WR-MCX MCX Straight Bulkhead Wrth Elektronik eiSos GmbH & Co. KG ORDER CODE EMC & Inductive Solutions Jack Crimp Type Max-Eyth-Str. 1 60626421110420 74638 Waldenburg Germany SIZE/TYPE BUSINESS UNIT STATUS PAGE Tel. +49 (0) 79 42 945 - 0 www.we-online.com For Flexible Cable RG178/RG196 eiCan Valid 1/5 eiSos we-online.com This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance. O 5 O 5,1 0.05 1,22 1,8 0,96 0,4 0,03 0,9 2,6 3,9 4,5 0.05Material Properties: Electrical Properties: Insulator Material PTFE Properties Test conditions Value Unit Tol. Insulator Color White Insertion Loss IL DC~3 GHz 0.25 dB max. R Center Contact Material Beryllium Copper Insulation Resistance 500 V (DC) in 120 sec. 1000 M min. ISO Center Contact Plating Gold, min. 0.076m over Nickel Contact Resistance Initial 1) R DC 0.2 V / 1 A 5 m max. Body Material Brass Contact Resistance After Test 2) R DC 0.2 V / 1 A 15 m max. Body Plating Gold, min. 0.076m over Nickel Contact Resistance Initial 3) R DC 0.2 V / 1 A 2.5 m max. Spacer Material Brass Contact Resistance After Test 4) R DC 0.2 V / 1 A 7.5 m max. Spacer Plating Gold, min. 0.076m over Nickel Withstanding Voltage 500 V (AC) in 60 sec. 750 V (RMS) min. Ferrule Material Copper 1) Center Contact 2) Center Contact Ferrule Plating Gold, min. 0.076m over Nickel 3) Outer Contact Nut Material Brass 4) Outer Contact Electrical properties may differ according to use of cable type and perform of assembly by user. Nut Plating Gold, min. 0.076m over Nickel Lock Washer Material Brass Mechanical Properties: Lock Washer Plating Gold, min. 0.076m over Nickel Properties Value Unit Tol. Mating Cycle 500 Cycles Kind Properties: Force to Engage 63 N max. Interface IEC 61169-36 Force to Disengage 8 - 20 N Connector Type MCX Gender Jack Certification: Orientation Type Straight RoHS Approval Compliant 2011/65/EU&2015/863 REACh Approval Conform or declared (EC)1907/2006 General Information: Halogen Free Conform JEDEC JS709B Operating Temperature -55 up to +155 C Halogen Free Conform IEC 61249-2-21 Electrical Properties: Specific Recommendation: Properties Test conditions Value Unit Tol. In order to handle products correctly, please download our precaution guide (www.we-online.com/ Impedance Z DC~3 GHz 50 assembly instructions 60626421110420) Frequency Range f DC~3 GHz VSWR DC~3 GHz 1.3 max. CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION METHOD JaC 002.000 2021-11-19 DIN ISO 2768-1m DESCRIPTION WR-MCX MCX Straight Bulkhead Wrth Elektronik eiSos GmbH & Co. KG ORDER CODE EMC & Inductive Solutions Jack Crimp Type Max-Eyth-Str. 1 60626421110420 74638 Waldenburg Germany SIZE/TYPE BUSINESS UNIT STATUS PAGE Tel. +49 (0) 79 42 945 - 0 www.we-online.com For Flexible Cable RG178/RG196 eiCan Valid 2/5 eiSos we-online.com This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.