Dimensions: mm Properties: Material ABS Color Black 10,0 0,3 Type RJ45 Flammability Rating according to UL94 HB Certification: RoHS Approval Compliant 2011/65/EU&2015/863 REACh Approval Conform or declared (EC)1907/2006 Halogen Free Conform IEC 61249-2-21 Halogen Free Conform JEDEC JS709B 11,8 0,3 13,8 0,3 General Information: Operating Temperature -20 up to +60 C Storage Conditions (in original < 40 C < 75 % RH packaging) Moisture Sensitivity Level (MSL) 1 CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION METHOD JuSa 001.001 2021-09-28 DIN ISO 2768-1m DESCRIPTION WA-PCCA Plastic Caps for RJ45 Wrth Elektronik eiSos GmbH & Co. KG ORDER CODE EMC & Inductive Solutions Modular Jack Max-Eyth-Str. 1 726151101 74638 Waldenburg Germany BUSINESS UNIT STATUS PAGE Tel. +49 (0) 79 42 945 - 0 www.we-online.com eiCan Valid 1/3 eiSos we-online.com This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance. 12,0 0,3 23,5 0,4 11,2 0,3Storage Conditions: Cautions and Warnings: A storage of Wrth Elektronik products for longer than 12 months is not recommended. Within other effects, the terminals may suffer The following conditions apply to all goods within the product series of WA-PCCA of degradation, resulting in bad processability. Therefore, all products shall be used within the period of 12 months based on the day of Wrth Elektronik eiSos GmbH & Co. KG: shipment. Do not expose the components to direct sunlight. The storage conditions in the original packaging are defined according to DIN EN 61760-2. General: The storage conditions stated in the original packaging apply to the storage time and not to the transportation time of the components. This mechanical component is designed and manufactured for use in general electronic equipment. Wrth Elektronik must be asked for written approval (following the PPAP procedure) before incorporating the components into any Packaging: equipment in fields such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network, etc. where higher safety and reliability are The packaging specifications apply only to purchase orders comprising whole packaging units. If the ordered quantity exceeds or is especially required and/or if there is the possibility of direct damage or human injury. lower than the specified packaging unit, packaging in accordance with the packaging specifications cannot be ensured. Mechanical components that will be used in safety-critical or high-reliability applications, should be pre-evaluated by the customer. The component is designed and manufactured to be used within the datasheet specified values. If the usage and operation conditions Handling: specified in the datasheet are not met, the component may be damaged or dissolved. Do not drop or impact the components, the component may be damaged. The maximum permissible torques must be complied with to prevent mechanical destruction of the component and PCB. Wrth Elektronik products are qualified according to international standards, which are listed in each product reliability report. Wrth If a component is pre-assembled with an adhesive tape, the adhesive duration cannot be guaranteed. This depends on the surface Elektronik does not warrant any customer qualified product characteristics beyond Wrth Elektroniks specifications, for its validity and where the component will be mounted on. It also depends on the environmental conditions the component is exposed to. The customer sustainability over time. has to evaluate this for his specific application. The responsibility for the function of the application of the customer specific products and use in a particular customer design is always Violation of the technical product specifications will void the warranty. the full and autonomous responsibility of the customer. All technical specification for standard products also apply to customer specific Coated metal parts may have spots and/or deposits because of the rinsing and drying process during plating. The storage and products. processability are not affected. The temperature rise of the component must be taken into consideration. The operating temperature is comprised of ambient Product Specific: temperature and temperature rise of the component.The operating temperature of the component shall not exceed the maximum temperature specified. Cleaning and Washing: These cautions and warnings comply with the state of the scientific and technical knowledge and are believed to be accurate and reliable. However, no responsibility is assumed for inaccuracies or incompleteness. Washing agents used during the production to clean the customer application might damage or change the characteristics of the components. Washing agents may have a negative effect on the long-term functionality of the product. Using a brush during the cleaning process may damage the component. Therefore, we do not recommend using a brush during the PCB cleaning process. Potting and Coating: If the product is potted in the customer application, the potting material might shrink or expand during and after hardening. Shrinking could lead to an incomplete seal, allowing contaminants into the components. Expansion could damage the components. We recommend a manual inspection after potting or coating to avoid these effects. CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION METHOD JuSa 001.001 2021-09-28 DIN ISO 2768-1m DESCRIPTION WA-PCCA Plastic Caps for RJ45 Wrth Elektronik eiSos GmbH & Co. KG ORDER CODE EMC & Inductive Solutions Modular Jack Max-Eyth-Str. 1 726151101 74638 Waldenburg Germany BUSINESS UNIT STATUS PAGE Tel. +49 (0) 79 42 945 - 0 www.we-online.com eiCan Valid 2/3 eiSos we-online.com This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.