Dimensions: mm Applicable Cable Diameter: mm Electrical Properties: Properties Test conditions Value Unit Tol. Impedance 25 MHz 1 turn Z 25 MHz 47 25% Impedance 100 MHz 1 turn Z 100 MHz 88 25% Impedance 25 MHz 2 turns Z 25 MHz 174 typ. Impedance 100 MHz 2 turns Z 100 MHz 290 typ. 21 0,5 12,0 0,3 Certification: RoHS Approval Compliant 2011/65/EU&2015/863 REACh Approval Conform or declared (EC)1907/2006 Halogen Free Conform IEC 61249-2-21 <= 12.5 mm Scale - 1:1 13,0 0,4 General Information: Storage Temperature (in original -20 C up to +60 C packaging) Operating Temperature -25 up to +125 C Test conditions of Electrical Properties: +20 C, 33 % RH if not specified differently Scale - 1:1 CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION METHOD JHa 007.000 2021-07-20 DIN ISO 2768-1m DESCRIPTION WE-TOF EMI Suppression Toroidal Wrth Elektronik eiSos GmbH & Co. KG ORDER CODE EMC & Inductive Solutions Ferrite Max-Eyth-Str. 1 74270120 74638 Waldenburg Germany BUSINESS UNIT STATUS PAGE Tel. +49 (0) 79 42 945 - 0 www.we-online.com eiSos Valid 1/6 eiSos we-online.com This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.General Properties: Typical Impedance Characteristics: Properties Value Unit Tol. 1000 Cable Diameter Max. 12.5 mm Material 4 W 620 Initial Permeability 620 typ. i Curie Temperature T 150 C typ. C Test Cable AWG26 Test Cable Length 100 mm 100 10 1 1 10 100 1000 Frequency MHz 1 turn 2 turns CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION METHOD JHa 007.000 2021-07-20 DIN ISO 2768-1m DESCRIPTION WE-TOF EMI Suppression Toroidal Wrth Elektronik eiSos GmbH & Co. KG ORDER CODE EMC & Inductive Solutions Ferrite Max-Eyth-Str. 1 74270120 74638 Waldenburg Germany BUSINESS UNIT STATUS PAGE Tel. +49 (0) 79 42 945 - 0 www.we-online.com eiSos Valid 2/6 eiSos we-online.com This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance. Impedance