Dimensions: mm Recommended Land Pattern: mm Electrical Properties: Properties Test conditions Value Unit Tol. Inductance 100 kHz/ 100 mV L 2x1000 H 40% Maximum Impedance Z 3600 typ. max 2,7 2 3 Rated Current T = 40 K I 950 mA max. R 2 1 DC Resistance R 2x0.18 max. DC Leakage Inductance 1 MHz/ 1 mA L 5900 nH typ. S Insulation Test Voltage U 1000 V (AC) max. T Rated Voltage U 80 V R 1 4 6,22 0,1 3 4 10,32 8,7 0,300 Scale - 2:1 Schematic: General Properties: 0,6 0,100 It is recommended that the temperature of the component does not exceed +125C under worst case conditions 1 1 2 Ambient Temperature (refering to -40 C up to +85 C I ) R 2 4 3 Operating Temperature -40 C up to +125 C Storage Temperature (in original -20C up to +40C, 75% RH max. packaging) Test conditions of Electrical Properties: +20C, 33% RH if not specified differently Scale 2:1 Product Marking: Start of Winding CREATED CHECKED GENERAL TOLERANCE PROJECTION Wrth Elektronik eiSos GmbH & Co. KG METHOD Marking 102 (Inductance Code) EMC & Inductive Solutions KaS SBa DIN ISO 2768-1m Max-Eyth-Str. 1 DESCRIPTION 74638 Waldenburg Germany WE-SL5 SMD Common Mode Line Tel. +49 (0) 79 42 945 - 0 ORDER CODE Filter www.we-online.com 744272102 eiSos we-online.com REVISION STATUS DATE (YYYY-MM-DD) BUSINESS UNIT PAGE 006.003 Valid 2015-08-06 eiSos 1/6 This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance. 0,3 0,1 7,62 0,1 10 0,300 6,5 max. 8,92 2,7Typical Impedance Characteristics: Test Setup: 10000 1000 Common Mode 100 Differential Mode 10 1 0.1 1 10 100 1000 Frequency MHz Z (comm) Z (diff) CREATED CHECKED GENERAL TOLERANCE PROJECTION Wrth Elektronik eiSos GmbH & Co. KG METHOD EMC & Inductive Solutions KaS SBa DIN ISO 2768-1m Max-Eyth-Str. 1 DESCRIPTION 74638 Waldenburg Germany WE-SL5 SMD Common Mode Line Tel. +49 (0) 79 42 945 - 0 ORDER CODE Filter www.we-online.com 744272102 eiSos we-online.com REVISION STATUS DATE (YYYY-MM-DD) BUSINESS UNIT PAGE 006.003 Valid 2015-08-06 eiSos 2/6 This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance. Impedance