Dimensions: mm Recommended Land Pattern: mm Electrical Properties: Properties Test conditions Value Unit Tol. 2 3 Inductance L 10 kHz/ 0.1 mA 27 mH 30% L Leakage Inductance 100 kHz 253 H typ. 1 4 S Rated Current 70 C 0.6 A max. DC Resistance R 20 C 1.2 max. DC V Rated Voltage 50 Hz 250 V (AC) max. R V Insulation Test Voltage 50 Hz/ 5 mA/ 2 sec. 1500 V (AC) T 1 4 Certification: 2 3 O 18,5 max RoHS Approval Compliant 2011/65/EU&2015/863 6,0 REACh Approval Conform or declared (EC)1907/2006 16,0 Halogen Free Conform JEDEC JS709B Scale- 1:1 VDE Approval 40042531 ENEC 10 Approval 40042531 Schematic: 2,1 u0,1 r 0,1 max. General Information: 10,0 0,2 It is recommended that the temperature of the component does not exceed +125 C under worst case conditions 1 4 3 Operating Temperature -40 C up to +125 C Operating Temperature -40 up to +125 C 2 1 2 Storage Conditions (in original < 40 C < 75 % RH packaging) Storage Temperature (in original -20 C up to +60 C packaging) 5,0 0,2 Moisture Sensitivity Level (MSL) 1 Scale - 1:1 Temperature Rise < 55 K Product Marking: Marking 7446630027 (Partnumber) CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION METHOD SBa 004.004 2021-12-13 DIN ISO 2768-1m DESCRIPTION WE-LF SMD Common Mode Power Wrth Elektronik eiSos GmbH & Co. KG ORDER CODE EMC & Inductive Solutions Line Choke Max-Eyth-Str. 1 7446630027 74638 Waldenburg Germany SIZE/TYPE BUSINESS UNIT STATUS PAGE Tel. +49 (0) 79 42 945 - 0 www.we-online.com SH eiSos Valid 1/7 eiSos we-online.com This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance. 19,6 0,3 0,4 typ 23,3 max 11,5 max 4,0 24,6Typical Attenuation: Typical Impedance vs. Frequency: 70 1000000,0 60 100000,0 50 10000,0 40 1000,0 30 100,0 20 10,0 10 0 1,0 0,001 0,01 0,1 1 10 100 1000 0,001 0,01 0,1 1 10 100 1000 Frequency MHz Frequency MHz Z (comm) Z (diff) A (comm) A (diff) CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION METHOD SBa 004.004 2021-12-13 DIN ISO 2768-1m DESCRIPTION WE-LF SMD Common Mode Power Wrth Elektronik eiSos GmbH & Co. KG ORDER CODE EMC & Inductive Solutions Line Choke Max-Eyth-Str. 1 7446630027 74638 Waldenburg Germany SIZE/TYPE BUSINESS UNIT STATUS PAGE Tel. +49 (0) 79 42 945 - 0 www.we-online.com SH eiSos Valid 2/7 eiSos we-online.com This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance. Attenuation dB Impedance