Dimensions: mm Recommended Land Pattern: mm Electrical Properties: Properties Test conditions Value Unit Tol. Inductance L 10 MHz 1 H 10% Q-Factor Q 10 MHz 45 min. 3 Rated Current 1 I T = 20 K 50 mA max. R 1 1,2 Rated Current 2 I T = 40 K 660 mA max. R 2 DC Resistance R 0.4 max. DC Self Resonant Frequency f 85 MHz min. res 0,5 0,3 Certification: RoHS Approval Compliant 2011/65/EU&2015/863 REACh Approval Conform or declared (EC)1907/2006 2 0,2 Halogen Free Conform JEDEC JS709B Scale - 10:1 Halogen Free Conform IEC 61249-2-21 Schematic: General Properties: It is recommended that the temperature of the component does not exceed +125 C under worst case conditions Ambient Temperature (referring -55 up to +85 C to I ) R Operating Temperature -55 up to +125 C Storage Conditions (in original < 40 C < 75 % RH packaging) Moisture Sensitivity Level (MSL) 1 Test conditions of Electrical Properties: +20 C, 33 % RH if not specified differently Scale - 10:1 CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION METHOD MHB 007.001 2020-02-19 DIN ISO 2768-1m DESCRIPTION WE-MI SMT Multilayer Inductor Wrth Elektronik eiSos GmbH & Co. KG ORDER CODE EMC & Inductive Solutions Max-Eyth-Str. 1 7447905 74638 Waldenburg Germany SIZE/TYPE BUSINESS UNIT STATUS PAGE Tel. +49 (0) 79 42 945 - 0 www.we-online.com 0805 eiSos Valid 1/6 eiSos we-online.com This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance. 1,25 0,2 0,9 0,2 1Packaging Specification - Tape and Reel: mm W3 P0 K0 A D0 P2 T W1 close to center B C W2 Top Cover Tape D1 P1 T1 A A0 T2 detail B Carrier Tape End Feeding direction Start B Cover Tape Cover Tape Chip Cavity Sprocket Hole Embossment No Component Components No Component min.160mm min.100mm Cover Tape min. 400mm A B C D N W1 W2 W3 W3 Tolerance 2,0 min. min. min. min. +1,5 max. min. max. Packaging is reffered to the international standard IEC 60286-3:2013 Tape width 8 mm 178 1.5 12.8 20.2 50 8.4 14.4 7.9 10.9 A0 B0 W T T1 T2 K0 P0 P1 P2 D0 D1 E1 E2 F Tape type 2a Packaging unit Tolerance typ. typ. +0,3/ -0,1 ref. max. typ. typ. 0,1 0,1 0,05 +0,1/ -0,0 min. 0,1 min. 0,05 pcs. Value 1,70 2,50 8,00 0,25 0,10 1,40 4,00 4,00 2,00 1,50 0,30 1,75 6,25 3,50 Polystyrene 3000 - 4000 CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION METHOD MHB 007.001 2020-02-19 DIN ISO 2768-1m DESCRIPTION WE-MI SMT Multilayer Inductor Wrth Elektronik eiSos GmbH & Co. KG ORDER CODE EMC & Inductive Solutions Max-Eyth-Str. 1 7447905 74638 Waldenburg Germany SIZE/TYPE BUSINESS UNIT STATUS PAGE Tel. +49 (0) 79 42 945 - 0 Pull-of force www.we-online.com 0805 eiSos Valid 2/6 8 mm eiSos we-online.com Tape width 0,1 N - 1,0 N This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance. - 18 165 0 B0 F E2 E1 W D A N