Dimensions: mm Recommended Land Pattern: mm Electrical Properties: Properties Test conditions Value Unit Tol. Inductance L 1 MHz/ 5 mA 6.8 H 20% Rated Current 1 I T = 20 K 650 mA typ. R 1 Rated Current 2 I T = 40 K 950 mA typ. R 2 Saturation Current I L/L < 30 % 300 mA typ. SAT DC Resistance R 20 C 250 m 30% DC DC Resistance R 20 C 325 m max. DC 0,5 0,2 Self Resonant Frequency f 30 MHz min. res Q-Factor Q 1 MHz/ 5 mA 25 min. 1,0 1,2 1,0 Type High Saturation Current 2,5 0,2 Certification: Scale - 10:1 RoHS Approval Compliant 2011/65/EU&2015/863 REACh Approval Conform or declared (EC)1907/2006 Schematic: Halogen Free Conform JEDEC JS709B Halogen Free Conform IEC 61249-2-21 General Properties: It is recommended that the temperature of the component does not exceed +125 C under worst case conditions Ambient Temperature (referring -40 up to +85 C to I ) R Operating Temperature -40 up to +125 C Storage Conditions (in original < 40 C < 75 % RH packaging) Moisture Sensitivity Level (MSL) 1 Test conditions of Electrical Properties: +20 C, 33 % RH if not specified differently Scale - 10:1 CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION METHOD MHB 001.003 2019-05-07 DIN ISO 2768-1m DESCRIPTION WE-PMI Power Multilayer Inductor Wrth Elektronik eiSos GmbH & Co. KG ORDER CODE EMC & Inductive Solutions Max-Eyth-Str. 1 74479887268A 74638 Waldenburg Germany SIZE/TYPE BUSINESS UNIT STATUS PAGE Tel. +49 (0) 79 42 945 - 0 www.we-online.com 1008 eiSos Valid 1/7 eiSos we-online.com This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance. 2 0,2 1 0,2 2,2Typical Inductance vs. Current Characteristics: Typical Temperature Rise vs. Current Characteristics: 10,0 60.0 50.0 40.0 1,0 30.0 20.0 10.0 0,1 0.0 1 10 100 1.000 10.000 0.0 0.2 0.4 0.6 0.8 1.0 1.2 Current mA Current A CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION METHOD MHB 001.003 2019-05-07 DIN ISO 2768-1m DESCRIPTION WE-PMI Power Multilayer Inductor Wrth Elektronik eiSos GmbH & Co. KG ORDER CODE EMC & Inductive Solutions Max-Eyth-Str. 1 74479887268A 74638 Waldenburg Germany SIZE/TYPE BUSINESS UNIT STATUS PAGE Tel. +49 (0) 79 42 945 - 0 www.we-online.com 1008 eiSos Valid 2/7 eiSos we-online.com This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance. Inductance H Temperature Rise K