Dimensions: mm Drillhole specification for PCB: Properties: Properties Test conditions Value Unit Tol. Drill hole specification for chemical surfaces Color Black Insulator Material PBT (O 1,60 -0,03 ) min. 0,10 Contact Material Copper Alloy O 1,475 0,05 Contact Plating Tin Plastic Housing Flammability UL94 V-0 Rating 2,54 Execution Press-Fit 5,08 Pins 12 I Rated Current 20 C 120 A max. R Travel Contact Resistance R 1 m max. min. 25m copper max. 60m Certification: RoHS Approval Compliant 2011/65/EU&2015/863 Drillhole specification for PCB: REACh Approval Conform or declared (EC)1907/2006 Halogen Free Conform JEDEC JS709B Drill hole specification for HAL Halogen Free Conform IEC 61249-2-21 6,24 10,0 (O 1,60 -0,03 ) min. 0,10 General Information: O 1,45 0,05 Operating Temperature -45 up to +125 C Storage Conditions (for single 0 C up to + 40 C up to 75 % RH parts) Moisture Sensitivity Level (MSL) 1 Packaging Bulk max. 15m Sn min. 25m copper max. 60m Scale - 1,5:1 CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION METHOD SuPe 002.000 2021-05-24 DIN ISO 2768-1m DESCRIPTION WP-PLUG REDCUBE PLUG Wrth Elektronik eiSos GmbH & Co. KG ORDER CODE EMC & Inductive Solutions Max-Eyth-Str. 1 7464100 74638 Waldenburg Germany SIZE/TYPE BUSINESS UNIT STATUS PAGE Tel. +49 (0) 79 42 945 - 0 www.we-online.com Direct Plug Terminal eiCan Valid 1/3 eiSos we-online.com This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance. 3,5 5,5 q 14,3 0,3 18,1 2,54 7,62Packaging: Cautions and Warnings: The packaging specifications apply only to purchase orders comprising whole packaging units. If the ordered quantity exceeds or is The following conditions apply to all goods within the product series of REDCUBE Plug of lower than the specified packaging unit, packaging in accordance with the packaging specifications cannot be ensured. Wrth Elektronik eiSos GmbH & Co. KG: Handling: General: Due to heavy weight of connected cables, REDCUBE PLUG is limited in resistance to shock and vibration. This electromechanical component was designed and manufactured for use in general electronic equipment. The cable must be secured against vibration and movement. Wrth Elektronik must be asked for written approval (following the PPAP procedure) before incorporating the components into any These cautions and warnings comply with the state of the scientific and technical knowledge and are believed to be accurate and reliable. equipment in fields such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network, etc. where higher safety and reliability are However, no responsibility is assumed for inaccuracies or incompleteness. especially required and/or if there is the possibility of direct damage or human injury. Electromechanical components that will be used in safety-critical or high-reliability applications, should be pre-evaluated by the customer. The component is designed and manufactured to be used within the datasheet specified values. If the usage and operation conditions specified in the datasheet are not met, the component may be damaged or dissolved. Do not drop or impact the components, the component may be damaged. The responsibility for the applicability of the customer specific products and use in a particular customer design is always within the authority of the customer. Wrth Elektronik products are qualified according to international standards. Wrth Elektronik does not warrant any customer qualified product characteristics beyond Wrth Elektroniks specifications, for its validity and sustainability over time. Product Specific: Press-Fit Technology:Follow all instructions in the datasheet, especially:Drill-hole specifications.Wave and reflow soldering is not applicable.While press-fit process, PCB should be supported against bending.Chip formation due to material displacement is permitted. Storage Conditions: Products shall be used within the period of 12 months based on the day of shipment. Do not expose the components to direct sunlight. The storage conditions in the original packaging are defined according to DIN EN 61760-2. The storage conditions stated in the original packaging apply to the storage time and not to the transportation time of the components. CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION METHOD SuPe 002.000 2021-05-24 DIN ISO 2768-1m DESCRIPTION WP-PLUG REDCUBE PLUG Wrth Elektronik eiSos GmbH & Co. KG ORDER CODE EMC & Inductive Solutions Max-Eyth-Str. 1 7464100 74638 Waldenburg Germany SIZE/TYPE BUSINESS UNIT STATUS PAGE Tel. +49 (0) 79 42 945 - 0 www.we-online.com Direct Plug Terminal eiCan Valid 2/3 eiSos we-online.com This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.