Dimensions: mm Recommended Land Pattern: mm Electrical Properties: Properties Test conditions Value Unit Tol. 0,6 Inductance L 100 kHz/ 100 mV 8 mA 350 H min. 1,0 0,05 DC Resistance R 100 kHz/ 100 mV 1000 m max. DC 24 13 Insertion Loss IL 1-100 MHz -1 dB max. 12 1 Return Loss RL 1-30 MHz 100 -18 dB min. Return Loss RL 30-60 MHz 100 -14 dB min. 24 13 1 Return Loss RL 60-80 MHz 100 -12 dB min. 12 Return Loss RL 80-100 MHz 100 -10 dB min. Differential to Common 1,0 0,4 0,1 DCMR 1-30 MHz -35 dB min. Mode Rejection Ratio 11,0 1) Differential to Common DCMR 30-60 MHz -35 dB min. Mode Rejection Ratio no vias or traces underneath the component 15,1 0,25 Scale - 2,5:1 Differential to Common DCMR 60-100 MHz -30 dB min. Mode Rejection Ratio Schematic: Crosstalk CT 1-60 MHz -33 dB min. h 0,1 1:1 D1+ 2 23 X1+ Crosstalk CT 60-100 MHz -33 dB min. Insulation Test Voltage V 1 min. 1500 V (RMS) min. CD1 1 24 CX1 T 1) The minimum values remain the same for CMRR D1- 3 22 X1- 1:1 D2+ 5 20 X2+ General Information: CD2 4 21 CX2 Test conditions of Electrical Properties: +20 C, 33 % RH if not specified differently D2- 6 19 X2- Operating Temperature -40 up to +85 C 1:1 D3+ 8 17 X3+ Storage Conditions (in original < 40 C < 75 % RH CD3 7 18 CX3 packaging) Moisture Sensitivity Level (MSL) 1 D3- 9 16 X3- 1:1 D4+ 11 14 X4+ It is recommended that the temperature of the component does not exceed +85C under worst case conditions CD4 10 15 CX4 Scale - 2,5:1 D4- 12 13 X4- Product Marking: Pin 1 CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION METHOD Marking 749020023A JaB 003.000 2019-10-29 DIN ISO 2768-1m DESCRIPTION WE-LAN 10/100/1000 Base-T SMT Wrth Elektronik eiSos GmbH & Co. KG ORDER CODE EMC & Inductive Solutions Transformer 1 Port Max-Eyth-Str. 1 749020023A 74638 Waldenburg Germany BUSINESS UNIT STATUS PAGE Tel. +49 (0) 79 42 945 - 0 www.we-online.com eiSos Valid 1/6 eiSos we-online.com This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance. 7,1 0,25 0,9 0,05 10,0 0,25 0,25 0,15 4,25 max. 1,35 9,35Certification: RoHS Approval Compliant 2011/65/EU&2015/863 REACh Approval Conform or declared (EC)1907/2006 Halogen Free Conform JEDEC JS709B Halogen Free Conform IEC 61249-2-21 UL Approval E472316 UL-62368 CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION METHOD JaB 003.000 2019-10-29 DIN ISO 2768-1m DESCRIPTION WE-LAN 10/100/1000 Base-T SMT Wrth Elektronik eiSos GmbH & Co. KG ORDER CODE EMC & Inductive Solutions Transformer 1 Port Max-Eyth-Str. 1 749020023A 74638 Waldenburg Germany BUSINESS UNIT STATUS PAGE Tel. +49 (0) 79 42 945 - 0 www.we-online.com eiSos Valid 2/6 eiSos we-online.com This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.