R 8,15 Exploded View Dimensions: mm General Information: Properties Value Unit Tol. sectional drawing A-A Thread M12 x P1.0 PG9 Shielding Shielded Mount rear 1 Tightening Torque 1.5 N*m +1/-0 SW 19 2,5 Panel Thickness 4.5 mm max. Protection Class 1) IP 67 1) Only in mated and locked position Certification: 3 RoHS Approval Compliant 2011/65/EU&2015/863 A A REACh Approval Conform or declared (EC)1907/2006 Scale - 1:1 Recommended Panel Cutout: mm 2 7,15 Additional General Information: It is recommended that the temperature of the component does not exceed +85C under worst case conditions Operating Temperature -40 up to +85 C Storage Conditions (in original 4 < 40 C < 75 % RH packaging) Moisture Sensitivity Level (MSL) 1 Test conditions of Electrical Properties: +20 C, 33 % RH if not specified differently Scale - 2:1 Scale - 1:1 Partlist Position Description Base Material Plating Material CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION METHOD 1 Metal Body Brass Nickel LuRa 001.001 2021-04-07 DIN ISO 2768-1m 2 Inner Seal Silicon / DESCRIPTION 3 Outer Seal Silicon / WE-LANMX Assembly 4 Nut Brass Nickel Wrth Elektronik eiSos GmbH & Co. KG ORDER CODE EMC & Inductive Solutions Max-Eyth-Str. 1 749699910 74638 Waldenburg Germany SIZE/TYPE BUSINESS UNIT STATUS PAGE Tel. +49 (0) 79 42 945 - 0 www.we-online.com M12 eiSos Valid 1/6 eiSos we-online.com This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance. R 10,8Dimensions: mm sectional drawing A-A PG9 -18 M 12,0 x1,0 A A 13,5 SW 19 Scale - 1,4:1 CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION METHOD LuRa 001.001 2021-04-07 DIN ISO 2768-1m DESCRIPTION WE-LANMX Assembly Wrth Elektronik eiSos GmbH & Co. KG ORDER CODE EMC & Inductive Solutions Max-Eyth-Str. 1 749699910 74638 Waldenburg Germany SIZE/TYPE BUSINESS UNIT STATUS PAGE Tel. +49 (0) 79 42 945 - 0 www.we-online.com M12 eiSos Valid 2/6 eiSos we-online.com This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance. 13,5 1,1